The ARB6 series arc protection device integrates multiple functions such as protection, measurement, monitoring, control, communication, fault recording, event recording, etc. It can monitor arc signals, protect current or voltage signals in real time, and achieve arc protection function for 0.4kV~35kV medium and low voltage distribution systems.
Selection Table of Arc Protection Device
Selection Table for Arc Sensors
Actual diagram of arc protection device, arc sensor, and optical fiber
Outline and Opening Dimensions of arc Protection Device

Installation diagram of arc protection device
The arc sensor is equipped with a buckle bracket, which needs to be installed with holes. The opening size of the buckle bracket is 20mm (diameter).
Appearance and Opening Dimensions of Arc Sensor
The installation example of the arc sensor
| |
ARB6-A6 | ARB6-A12 | ARB6-A18 | ARB6-A24 | ARB6-A30 | ||
| Hardware | Arc sensor signal acquisition | 6 | 12 | 18 | 24 | 30 | |
| Current collection | 4 sets of 3-phase currents, a total of 12 current channels | ||||||
| Voltage acquisition | 3 zero sequence voltages, a total of 3 voltage channels | ||||||
| Digital Input | 5 | 22 | 5 | 22 | 5 | ||
| Digital Output | 14 normally open exits (including 4 High speed relay outlet) and 2 normally closed exits | ||||||
| 2 485 interface | √ | ||||||
| 1 Ethernet interface | √ | ||||||
| 3 Ethernet interface | optional | ||||||
| GPS timing interface | √ | ||||||
| USB interface | √ | ||||||
| Function | Arc protection | Arc criterion | √ | ||||
| Arc&Current criterion | √ | ||||||
| Arc&Voltage criterion | √ | ||||||
| Arc monitoring and fault location | √ | ||||||
| Real time self inspection of arc sensors and fiber optic links | √ | ||||||
| failure protection | √ | ||||||
| CT disconnection monitoring | √ | ||||||
| non-electricity protection | √ | ||||||
| Device abnormal alarm | √ | ||||||
| Maintenance status lock | √ | ||||||
| Fault recording | √ | ||||||
| Protocol | Modbus | √ | |||||
| IEC101 | √ | ||||||
| IEC103 | √ | ||||||
| IRIG-B | √ | ||||||
| LoopBack | √ | ||||||
Mechanical life: ≥10000
Switching capacity: ≥1000W,L/R = 40ms
On current: continuous ≥5A, short time(200ms)≥30A
Interrupting capacity: ≥30W,L/R = 40ms