Secured Trading Service

Acrel Am5 Series Substation Protection Relay up to 35kv

Jiangsu Acrel Electrical Manufacturing Co., Ltd.
  • Audited Supplier
  • 7 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Acrel Am5 Series Substation Protection Relay up to 35kv

Acrel Am5 Series Substation Protection Relay up to 35kv
Acrel Am5 Series Substation Protection Relay up to 35kv pictures & photos
Acrel Am5 Series Substation Protection Relay up to 35kv
Acrel Am5 Series Substation Protection Relay up to 35kv pictures & photos
Acrel Am5 Series Substation Protection Relay up to 35kv
Acrel Am5 Series Substation Protection Relay up to 35kv pictures & photos
Acrel Am5 Series Substation Protection Relay up to 35kv
Acrel Am5 Series Substation Protection Relay up to 35kv pictures & photos
Acrel Am5 Series Substation Protection Relay up to 35kv
Acrel Am5 Series Substation Protection Relay up to 35kv pictures & photos
Acrel Am5 Series Substation Protection Relay up to 35kv
Acrel Am5 Series Substation Protection Relay up to 35kv pictures & photos
Acrel Am5 Series Substation Protection Relay up to 35kv
  • Acrel Am5 Series Substation Protection Relay up to 35kv
  • Acrel Am5 Series Substation Protection Relay up to 35kv
    Acrel Am5 Series Substation Protection Relay up to 35kv
  • Acrel Am5 Series Substation Protection Relay up to 35kv
    Acrel Am5 Series Substation Protection Relay up to 35kv
  • Acrel Am5 Series Substation Protection Relay up to 35kv
    Acrel Am5 Series Substation Protection Relay up to 35kv
  • Acrel Am5 Series Substation Protection Relay up to 35kv
    Acrel Am5 Series Substation Protection Relay up to 35kv
  • Acrel Am5 Series Substation Protection Relay up to 35kv
    Acrel Am5 Series Substation Protection Relay up to 35kv
  • Acrel Am5 Series Substation Protection Relay up to 35kv
    Acrel Am5 Series Substation Protection Relay up to 35kv

Find Similar Products

Product Description

Multifunctional Protection Relay for Transformer Substation
The AM5 series microcomputer protection device integrates protection, measurement, and control functions. It is suitable for substations and distribution stations with a voltage level of 35kV and below, and realizes protection and automatic control functions for equipment such as lines, bus ties, distribution transformers, high-voltage motors, and high-voltage capacitors. Its application fields cover industries such as electric power, water conservancy, transportation, petroleum, chemical industry, coal, and metallurgy.
 
Acrel Am5 Series Substation Protection Relay up to 35kv
Can measure 2~11th harmonics and has overcurrent protection function with second harmonic braking

Independent operation circuit, can adapt to 0.25~5A switch tripping and closing current

10 channels of passive switch output customizable, 16 channels of active switch input customizable

Supports USB port upgrade, and export of setting values/event records/fault recording

Supports Modbus and IEC 60870-5-103 communication protocols
 

Acrel Am5 Series Substation Protection Relay up to 35kv

Product Parameters

Function Specification
-F -C -M -T -B -U1 -DB
Hardware
Resource
Current acquisition 8 8 8 8 6 0 6
Voltage acquisition 4 4 4 4 6 4 6
Switch Collection 16 16 16 16 16 16 16
Relay Output 10 10 10 10 10 10 10
Protection Three-stage overcurrent protection √     √      
Three-stage overcurrent with direction blocking √            
Two-stage overcurrent protection   √ √   √   √
Zero-sequence overcurrent protection √ √ √ √      
Inverse time overcurrent protection √ √ √ √ √    
Overload protection √   √ √      
Control circuit disconnection alarm √ √ √ √ √   √
Under-voltage protection     √     √alarm  
Lack of voltage protection √            
PT disconnection alarm √ √ √ √ √ √ √
Three-phase one-time reclosing √            
Low-frequency load shedding √            
High-frequency protection √            
After accelerating overcurrent √       √   √
Overvoltage protection √ √ √     √alarm √alarm
Locked-rotor protection              
Undervoltage protection   √          
Unbalanced voltage protection   √ √        
Unbalanced current protection   √ √        
Phase error protection     √        
Zero sequence overvoltage protection √ √ √     √alarm  
Non-electric protection √ √ √ √      
Starting over time     √        
Reverse power protection √            
Thermal overload protection     √        
Negative sequence overcurrent
(two stages / inverse time limit)
    √        
Incoming line / busbar         √   √
Busbar charging protection         √    
FC blocking √ √ √ √      
Second harmonic blocking √ √ √ √      
Intermittent ground protection √ √          
Overhaul status lockout √ √ √ √ √ √ √
Communication protocol ModBus-RTU √ √ √ √ √ √ √
IEC60870-5-103 √ √ √ √ √ √ √
Accessibility Fault recorder √ √ √ √ √   √
IRIG-B time synchronization √ √ √ √ √ √ √

 

 

Acrel Am5 Series Substation Protection Relay up to 35kv

Dimension

Acrel Am5 Series Substation Protection Relay up to 35kv

 

Display

Acrel Am5 Series Substation Protection Relay up to 35kv

Wiring

Acrel Am5 Series Substation Protection Relay up to 35kv

 

Networking

Acrel Am5 Series Substation Protection Relay up to 35kv

FAQ

Q: How to set the CT and PT ratio of the protection device?

A: The protection device can set the CT and PT ratio through the fixed value menu. For example, if the current transformer is 75/5 and the voltage transformer is 10/0.1, then the CT ratio is set to 15 and the PT ratio is set to 100.


Q: For AM5, if you want to place single circuit protection and transformer protection, how to distinguish the model?

A: AM5-F is suitable for line protection and transformer protection.No need to distinguish between models when placing orders


Q: When the voltage is a three-phase three-wire system, does the current have to be connected with 2CT?

A: The voltage wiring mode and current wiring mode of the protection device can be set independently, and can be connected freely.


Q: How to confirm whether the anti-trip function is configured?

A: If the circuit breaker is equipped with anti-trip, the device does not must be equipped with anti-trip; if the circuit
breaker does not have anti-trip, you need to configure the AM5-FT anti-trip module. (If DC48V is selected as the
operating power supply, the anti-trip box is not optional, and the circuit breaker must be equipped with anti-trip
function; if you choose AC anti-trip, please note that AC and DC general anti-tripping)


Q: How to purchase suitable protection devices?

A: Before ordering, it is recommended to consult related engineers, select the appropriate protection model,
and then fill in the corresponding selection table, and place the order after confirmation by the engineers.

Related Products

Specification AM2SE AM3SE AM4 AM5 AM5SE
Hardware Protect Current 3 channels 3 channels 3 channels 3 channels 3 channels
Measure Current × × × 3 channels 3 channels
zero-sequence current 1 channel 2 channels 1 channel 2 channels 2 channels
Measure Voltage 3 channels 3 channels 4 channels 4 channels 4 channels+ backup 2 channels
Switch Value Input 8 channels 11 channels 12 channels 16 channels 20 channels
Switch Value Output 5 channels 5 channels 5 channels 10 channels 10 channels
RS485 Interface 1 channel 1 channel 1 channel 2 channels 2 channels
RS232 Interface × × 1 1 1
USB × √
CE × optional 2
GPS time synchronization × √ × √ √
4-20mA × optional 2
Anti-jump Optional external anti-hop module built-in
operation circuit × √
Protection Main transformer differential protection × × × × √
Main transformer backup protection × × × × √
Three-stage overcurrent
With direction with a voltage blocking
× × × √ √
Three-stage overcurrent
with directional locking
× √ √ √ √
Three-stage overcurrent √ √ √ √ √
Zero sequence overcurrent protection √ √ √ √ √
Overvoltage protection √ √ √ √ √
Low voltage protection √ √ √ √ √
Zero sequence overvoltage protection √ √ √ √ √
High-power motor differential protection
(>2000KW)
× × × × √
High Voltage Motor Protection × × × √ √
Capacitor Protection × × × √ √
Overcurrent after acceleration √ √ √ √ √
Low-frequency load shedding √ √ √ √ √
Grid-connected reverse power protection × × × √ √
PT disconnection alarm √ √ √ √ √
Fault alarm √ √ √ √ √
FC blocking √ √ √ √ √
Incoming line of high voltage single busbar system
/Mother-joint prepared self-injection
× × × √ √
Low-voltage standby self-switching(400V) × × × √ ×
PT monitoring and parallel functions × × × × √
PT monitoring functions √ √ √ √ √
Non-electrical protection
(temperature, gas, etc.)
√ √ √ √ √
Synchronization function × × × × √
Fault recorder √ √ √ √ √
Electrical parameter measurement U, I, Fr, P, Q, PF, Ep, Eq, Es

Company Profile

Acrel Am5 Series Substation Protection Relay up to 35kv

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR2541377". Items marked "verified" are certified.

Watch Video
Watch Video
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
No. 5, Dongmeng Road, Dongmeng Industrial Park, Nanzha Street, Jiangyin City, Wuxi, Jiangsu, China
verified Number of Employees
307
verified Registered Capital
326,860,200 RMB
verified Terms of Payment
LC, T/T, PayPal, D/P, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shanghai Port
verified Minimum Order Quantity
1 PC
verified Supply Chain Partners
164

Our Production Capability & Technical Expertise

Main Products
Power Meter, Energy Meter, WiFi Meter, RS485 Modbus-RTU Meter, Multifunction Relay, Motor Protection Relay, Busbar Temperature Sensor, Power Tag, Insulation Monitor, Current Sensor
verified Production Lines
3
verified Production Machines
SMT Line, Assembling Line, Auto Processing Line
verified QA/QC inspectors
24 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
32 people
verified Traceability of Raw Materials
Yes
verified Test Reports for Raw Materials
UL, Others

Our Industry Experience & Global Business Record

verified Year of Establishment
2004-12-14
verified Export Year
8 Years
verified Main Markets
North America, Europe, Southeast Asia/ Mideast
verified Repeat Buyers Choice
80%~100%
verified Number of Foreign Trading Staff
18
verified Overseas Agent/Branch
Yes
verified New Products Launched in Last year
Yes

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now