• Power Analyzer Meter From Acrel Factory for Solar Project
  • Power Analyzer Meter From Acrel Factory for Solar Project
  • Power Analyzer Meter From Acrel Factory for Solar Project
  • Power Analyzer Meter From Acrel Factory for Solar Project
  • Power Analyzer Meter From Acrel Factory for Solar Project
  • Power Analyzer Meter From Acrel Factory for Solar Project

Power Analyzer Meter From Acrel Factory for Solar Project

After-sales Service: Yes
Warranty: 2 Years
Display: Digital
Samples:
US$ 248.5/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Power Analyzer Meter From Acrel Factory for Solar Project pictures & photos
Power Analyzer Meter From Acrel Factory for Solar Project
US $248.5-518 / Piece
Min. Order: 1 Piece
Diamond Member Since 2020

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory, Trading Company
  • Overview
  • Panel
  • Function
  • Wiring
  • Product Parameters
  • Specification
  • Installation
  • Networking
  • Company Profile
Overview

Basic Info.

Model NO.
APM
Installation
Direct Connected
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment
Three-phase Four-wire
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Customized
Phase
3p3l, 3p4l
Accuracy
0.2s, 0.5s Grade
Rated Voltage
AC 100V, 110V, 400V, 690V
Rated Current
AC 1A, 5A
Frequency
45-65Hz
Analog Input
DC 0-20mA, 4-20mA, 0-5V, 1-5V
Analog Output
DC 0-20mA, 4-20mA, 0-5V, 1-5V
SD / TF Card
32g
Protocol
Modbus-RTU, Dlt645, Profibus-Dp, Modbus-TCP, HTTP
Interface
RS485, RS232, RJ45
Digital
8di/2do
Analog
8ai /4ao
Transport Package
Carton
Specification
APM
Trademark
Acrel
Origin
China
HS Code
9028301400
Production Capacity
200000

Packaging & Delivery

Package Size
20.00cm * 15.00cm * 10.00cm
Package Gross Weight
0.500kg

Product Description

Solar Watt and Power Analyzer Meter from Acrel Factory

Power Analyzer Meter From Acrel Factory for Solar Project

APM series power meters of ACREL are power meters that are designed according to IEC standards and synchronized with international advanced technology. APM series meters have full power measurement, energy statistics, analysis of power quality and network communications, and other functions that are mainly used for comprehensive monitoring of the quality of the power supply network.

This series of meters use a modular design, with a rich function of the external DI / DO module, AI / AO module, event recording (SOE) module with T-Flash (TF) card, network communication module, can achieve full power measurement of an electrical circuit and monitoring of switch status, Dual RS485 with Ethernet interface can realize data copying of RS485 master station, eliminating the need for data switching exchange. PROFIBUS-DP interface can realize high-speed data transmission and networking functions.
 

Panel

Power Analyzer Meter From Acrel Factory for Solar Project
Power Analyzer Meter From Acrel Factory for Solar Project
Power Analyzer Meter From Acrel Factory for Solar Project
 
(1)
MD82: 8DI+2DO
(2)
MA84: 8AI+4AO
(3)
MLOG: SD card
(4)
MCM: RS485 communication
(5)
MCE: CE communication
(6)
MCP: Profibus-DP communication
(7)
MTN: 4 channels of NTC temperature with 2m or 4m
(8)
MTP: 2 channels of PT100 temperature
(9)
MTH: 1 channel of Temperature and Humidity Control
Power Analyzer Meter From Acrel Factory for Solar Project

Function

Power Analyzer Meter From Acrel Factory for Solar Project

Wiring

Power Analyzer Meter From Acrel Factory for Solar Project


Power Analyzer Meter From Acrel Factory for Solar Project
Power Analyzer Meter From Acrel Factory for Solar Project

Product Parameters

 

Technical Parameters Index
Signal Electrical network Three-phase three-wire, three-phase four-wire, see the wiring diagram;
Frequency 45~65Hz;
Voltage Rated value:AC 100V,110V,400V,690V;
Overload: 1.2 times rated value(continuous); 2 times rated value /1 second;
Power consumption: < 0.5VA (per channel);
Current Rated value: AC 1A, 5A, support 4 mm2 line access;
Overload: 1.2 times rated value(continuous); 10 times rated value/1 second;
Power consumption: < 0.5VA (per channel);
Measurement accuracy Voltagecurrent and power class 0.5s/class 0.2s (APM800,APM810/APM801)
Active power class 0.5s/class 0.2s (APM800,APM810/APM801)
Reactive power class 2
Harmonic 1%(2rd~42nd),2%(43rd~63rd)
Switch inputs Dry contact inputs, built-in power supply;
Relay outputs Contact type: open contact in the main part, changeover contact in the module;
Contact capacityAC 250V/3A  DC 30V/3A;
The pulse output of energy Output mode: Optocoupler pulse with open collector;
Pulse constant:4000(5A),8000(1A) imp/kWh;
Analog outputs DC 0mA~20mA,4mA~20mA,0V~5V,1V~5V output, accuracy class 0.5%, load resistance ≤ 500Ω;
Analog inputs DC 0mA~20mA,4mA~20mA,0V~5V,1V~5V iutput, accuracy class 0.5%
Storage card Standard Capacity:4G, TF Card Up to 32G Capacity;
Communication RS485 interface/Modbus-RTU protocol and DLT645 protocol
Profibus-DP interface/Profibus-DP protocol;
RJ45 interface (Ethernet) / Modbus-TCP, HTTP, DHCP and other protocols;
Power supply Working range: AC/DC 85V~265V or AC/DC 115~415V(P2);
Power consumption: Power consumption of the main part ≤ 15VA;
Safety Power frequency withstands voltage The power frequency withstands voltage between the shell and the auxiliary power supply, each input and output terminal group is AC 4kV/1min;
The power frequency withstand voltage between the auxiliary power supply and each input and each output terminal group is AC 2kV/1min;
The power frequency withstand voltage between the voltage input and other input/output terminal groups are AC 2kV/1min;
The power frequency withstand voltage between the current input and other input/output terminal groups are AC 2kV/1min;
The power frequency withstand voltage between the relay output and other input/output terminal groups are AC 2kV/1min;
The power frequency withstand voltage between each terminal group of switch input, communication, analog output, and pulse output is AC 1kV/1min;
Insulation resistance Inputs outputs to the shell>100MΩ;
Electromagnetic compatibility Meet IEC 61000 standard (Level 4);
Protection level Display panel IP52
Environment Operating temperature: -20 °C ~ +65 °C;
Storage temperature: -20°C~+70°C;
Relative humidity: ≤95% without condensation;
Altitude: ≤2500m;
Standards IEC 60068-2-1 Environmental Testing-Part 2-1:Tests Test A: Cold IDA
IEC 60068-2-2 Part 2-1:Tests Test B: Dry heat
IEC 60068-2-30 Part 2-30:Tests Test Db:Damp heat,cyclic(12+12h)
IEC 61000-4 Electromagnetic compatibility-Testing and measurement techniques
IEC 61557-12 Electrical safety in low voltage distribution system up to 1000V a.c. and1500V d.c -Equipment for testing, measuring or monitoring of protective measures- Part12:Performances measuring and monitoring devices(PMD)
IEC 62053-22 Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2s and 0.5s)

Specification

Function Function description APM800
(class 0.5s)
APM801
(class 0.2s)
APM810
(class 0.5s)
APM830
(class 0.2s)
Parameters All parameters
Four-quadrant energy
Multi-rate energy
The pulse output of energy Active/reactive
Demand Real-time and maximum demand of I, P, Q, S (with time)
Extreme value statistics Extremum of I, UL-L, UL-N, P Q, S, PF, F, THDi, THDuin this month and last month (with time)
Power quality Unbalance of I, UL-L, UL-N
Voltage phase angle, current phase angle
The total and 2nd-63rd harmonic content of voltage and current × ×
Voltage crest factor × ×
Telephone waveform factor × ×
Current K-factor × ×
Positive sequence, negative sequence,zero-sequence voltage, and current × × ×
Fundamental voltage and current × × ×
Waveform Waveform trace display × × ×
Fault waveform record × × ×
Alarm A total of 66 kinds of alarm types, each type can record the most recent 16 alarm records, support extended records by TF card
Event Record the most recent 128 event records, support extended records by TF card
Communication RS48(Modbus-RTU)
Digital I/O 2DI+2DO
Optional functions MD82 8DI+2DO  Digital
MLOG TF or Micro SD card 32G
MA84 8Al+-4AO  Analog
MCM 1 RS485(Modbus-RTU), support master mode or slave mode
MCP 1 Profibus(Profibus-DP)
MCE 1 Ethernet(Modbus-TCP, HTTP, DHCP)
Note:
(1) Accuracy of 2-42nd harmonic measurement in the frequency range of 45~65Hz is 1%, and the accuracy of 43-63rd harmonic measurement in the frequency range of 50Hz is 2%.
(2)"★":standard   "×":No   "☆":Optional

 

Installation

Power Analyzer Meter From Acrel Factory for Solar Project

 

Networking

Power Analyzer Meter From Acrel Factory for Solar Project

Company Profile

Power Analyzer Meter From Acrel Factory for Solar Project

Acrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Power Analyzer Meter From Acrel Factory for Solar Project pictures & photos
Power Analyzer Meter From Acrel Factory for Solar Project
US $248.5-518 / Piece
Min. Order: 1 Piece
Diamond Member Since 2020

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory, Trading Company
Registered Capital
10000000 RMB
Plant Area
>2000 square meters