• Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA
  • Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA
  • Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA
  • Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA
  • Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA
  • Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA

Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA

Type: Electromagnetic
Output Signal Type: Analog Output
Production Process: Integration
Samples:
US$ 23.15/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA pictures & photos
Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA
US $23.15-49.6 / Piece
Min. Order: 1 Piece
Diamond Member Since 2020

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Specification
  • Product Parameters
  • Installation Instructions
  • Wiring
  • After Sales Service
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
BA(II)
Material
Plastic
Accuracy Grade
0.5G
Application
PLC, Energy Meter
IP Rating
IP40
Certification
CE, RoHS
Customized
Customized
Input
AC 0-600A
Output
DC4-20mA, DC0-20mA, DC1-5V, DC0-5V
Auxiliary Power
DC12V, DC24V
Communication
RS485, Modbus-RTU
Transport Package
Carton
Specification
BA(II)
Trademark
Acrel
Origin
China
HS Code
9030339000
Production Capacity
200000

Packaging & Delivery

Package Size
17.00cm * 15.00cm * 13.00cm
Package Gross Weight
0.500kg

Product Description

Product Description

Monitoring application of BA current sensor to the water pump in the sewage treatment industry
       In the whole process of sewage treatment, the water pump plays a vital role as the main transmission equipment of water. Since there are many water pumps in the sewage treatment plant, if there is a problem with the water pump at one of the joints, it is likely to cause the previous procedure. Excessive accumulation of sewage in the next program and lower than normal level of sewage in the next program, so that the entire sewage treatment program is in a semi-paralyzed state, and the staff cannot conduct inspections on all the pumps.
      Based on the above-mentioned situation of unmanned inspection of water pumps and circulating pumps in the sewage treatment industry, BA series AC current transmitters can be used for monitoring, and the power status of the water pumps can be known at the first time, and the data of BA sensors can be collected through PLC or DSC system. Transmit data to correctly judge the normal working condition of the pump.

Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA

Specification

Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA
Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA
 
Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA
Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA
 
Specification Input Current Output Signal Inner Size(mm) Type Optional Function  
BA20(II)-AI/I AC 0-200A DC 4-20mA, DC 0-20mA 20 Average value C:RS485; F:Split type  
BA20(II)-AI/V AC 0-200A DC 1-5V, DC 0-5V 20 Average value C:RS485; F:Split type  
BA20(II)-AI/I-T AC 0-200A DC 4-20mA, DC 0-20mA 20 True effective value C:RS485; F:Split type  
BA20(II)-AI/V-T AC 0-200A DC 1-5V, DC 0-5V 20 True effective value C:RS485; F:Split type  
BA50(II)-AI/I AC 0-600A DC 4-20mA, DC 0-20mA 50 Average value C:RS485; F:Split type  
BA50(II)-AI/V AC 0-600A DC 1-5V, DC 0-5V 50 Average value C:RS485; F:Split type  
BA50(II)-AI/I-T AC 0-600A DC 4-20mA, DC 0-20mA 50 True effective value C:RS485; F:Split type  
BA50(II)-AI/V-T AC 0-600A DC 1-5V, DC 0-5V 50 True effective value C:RS485; F:Split type  
BA50L(II)-AI/I AC 0-1A DC 4-20mA, DC 0-20mA 50 Average value C:RS485; F:Split type  
 

Product Parameters

 
Technical parameter Index
Accuracy class Class 0.5
Input Nominal value BA20(I)-AI Current AC 0.5A, 50A,200A, etc.AC 0~(0.5~200)A
BA50(II-AI Current AC 60A. 300A, 600A, etc. AC0~(60-600)A
BA50L(I)-AI Current AC0.1A,1A. etc. AC0~(0.1~1)A
Overload Continuous 1.2 times, instantaneous current 10 times/1S
Absorbed power ≤1VA
Frequency response 25Hz~800Hz, especially suitable for industrial frequency occasions
Output Nominal value DC4~20mA, or 0~20mA,0~5V,0~10V (1) etc.
Load Resistance When DC12V power supply, current output is ≤250Ω
When DC24V power supply, current output is ≤500Ω
When voltage output is≥1KΩ
Communication RS485 interface/Modbus-RTU (2)
Response time ≤400ms
Power supply Voltage DC12V or 24V
Power consumption ≤1W
Insulation resistance >100MΩ
Compressive strength Between input/output and power supply 2.0KV/min,50Hz
Temperature Coefficient -10ºC~+55ºC, ≤400ppm/ºC
Environment Temperature Work: -10ºC~+55ºC Storage: -25ºC~+70ºC
Humidity ≤93%RH, no condensation, no corrosive gas place
Altitude ≤2000m
Installation method TS35mm Din-rail, or use screws to fix the cabinet

Notes:
(1)  0~10V output is only suitable for DC24V power supply;
(2)  The communication function is optional.

Installation Instructions

Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA

Wiring

Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA

 

After Sales Service

Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA

Certifications

Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA

Company Profile

Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA

Acrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.
 

Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mABa (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA pictures & photos
Ba (II) Series AC Current Transmitter Monitoring Application of Water Pump in Sewage Treatment Industry PLC Dcs 4-20mA
US $23.15-49.6 / Piece
Min. Order: 1 Piece
Diamond Member Since 2020

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory, Trading Company
Registered Capital
10000000 RMB
Plant Area
>2000 square meters