Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function

Product Details
Customization: Available
Input Voltage: DC0-1000V
Input Current: Split: 0-75mA; Hall: 0-20mA, 4-20mA, 0-5V, 0-10V
Still deciding? Get samples of US$ 98.5/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Arabic
Experienced Team
The supplier has 42 foreign trading staff(s) and 33 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (17)
  • Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
  • Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
  • Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
  • Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
  • Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
  • Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
Find Similar Products
  • Overview
  • Product Description
  • DC Meter Function & Parameter
  • Network
  • DC Power Meter Installation
  • DC Power Meter Application
  • FAQ
  • Company Profile
Overview

Basic Info.

Model NO.
DJSF1352-RN
Auxiliary Power
DC24V, DC48V, AC/DC85V-265V
Interface
RS485, Infraed
Protocol
Modbus-RTU, Dl/T645-2007
Switch Value
2di/2do
After-Sales Service
Yes
Type
Fast EV Charging Station
Certification
CE, ISO, RoHS
Warranty
2 Years
Transport Package
Carton
Specification
DC
Trademark
Acrel
Origin
China
HS Code
9030849000
Production Capacity
200000

Packaging & Delivery

Package Size
17.00cm * 15.00cm * 13.00cm
Package Gross Weight
1.000kg

Product Description

Product Description

Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
Measurement: kWh, kVarh, Power, Current, Voltage and etc
Current Rating: -/75mV (with Shunt); -/4~20mA (with Hall Sensor)
Voltage Rating: 0~1000V DC
Application: DC Battery; Charging Pile; Solar PV and etc
Communication: RS485 (MODBUS-RTU)
Extra Function: Dual DC Circuits Monitoring; Secondary RS485 (MODBUS-RTU); Built-in Bipolar Power Source (for Hall Sensors); DO/DI Function
Display: LCD Display
Dimension: 72*71*87.8mm (L*W*H)
Installation: 35mm DIN Rail
Power Supply: 85~265V AC/DC; 24V(±10%) DC; 48V(±10%) DC
Standard&Certificate: CE

Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
 

DJSF1352-RN rail-mounted DC power meter with double DC input channels, designed for telecommunications base stations, DC charging piles, solar photovoltaic and other applications, this series of meters can measure the voltage, current, power and forward and reverse energy and so on in the DC system.The actual use of the site, you can measure the total power, but also measure the energy within a specified period of time. The test results can be used for local display, but also with industrial control equipment, computers to form a measurement and control system.

The meter can have infrared communication interface and RS-485 communication interface, and supports Modbus-RTU protocol and DLT645-97 (07) protocol at the same time.The meter can have relay alarm output and digital input function;You can set the ratio, alarm, and communication through the meter panel keys according to different requirements.The meter can have event recording of switch (Modbus protocol), programming and event setting records (645 protocol), instantaneous and timing freeze function of data (645 protocol), maximum and minimum value recording function of voltage and current power. 

 

 

DC Meter Function & Parameter

Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function

Dual Independent DC Circuits Monitoring

 For Twin EV Charger&Battery

 Voltage Input:DC 0~1000V

 Current Input (by Shunt): 0~75mV

 Current Input (by Hall Sensor): 0~5V, 0~10V, 0~20mA, 4~20mA

Built-in Bipolar Power Source

 Power Supply for Hall Effect CT

 Range: DC -12V ~ DC +12V

Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function

Optional Dual RS485 Communication

 Protocol: MODBUS-RTU

 1 RS485 (standard)

DO/DI Function

 2 DO (2A/30V DC; 2A/250V AC)

 2 DI (dry contact)

Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function

LCD Display

 Parameter Display

 Programming Interface

Keypads HMI for Programming

 Parameter Display Setting

 Communication

Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
Technical parameters Indicators
Input Nominal value Voltage input range Current input
DC 0-1000V Shunt:0-75mV;
   
See the physical wiring diagram Hall sensor:0-20mA,4-20mA,0-5V,0-10V and so on
Overload 1.2 times rated (continuous); 2 times rated/1 second;
Power consumption Voltage: ≤0.2VA, current ≤0.1VA
Accuracy class Class 1
Function Display 8-bit segment LCD screen (LCD)
Communication Interface RS485, infraredRS485, infrared
Communication protocol Modbus-RTU,DL/T 645-2007
Switch Switch output 2 Relay outputs, 2A/30VDC or 2A/250VA
Switch input 2 dry contact inputs
Pulse output A second pulse output, a energy pulse output
See the SYS->PLUS display in the meter menu setting
 
For example: The meter displays 100, which is 100imp/kWH
Power Supply Voltage range AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)
Power consumption ≤ 3W
Power frequency withstand voltage Power supply // Voltage input // Current input // Relay output and switch input // Communication interface / / Pulse output 3kV/1minPower supply // Relay output // Voltage input // Current input 3kV/1minPulse output // Communication interface // Switch input 2kV/1min
Insulation resistance ≥ 40M Ω
Average barrier-free working hours ≥50000h
Environment Temperature Normal operating temperature: -25 °C ~ +65 °C;
 
Limit working temperature: -40 °C ~ +70 °C;
 
Storage temperature: -40ºC~+80ºC
Humidity ≤93%RH, no condensation, no corrosive gas
Altitude ≤2500m

Network

Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function

 

DC Power Meter Installation

Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function

Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
 
Wiring with Shunt Wiring with Hall Sensor
 

DC Power Meter Application

 

Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
 
Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function

FAQ

 


Q:DJSF1352-RN Installation? 

A:DJSF1352-RN use 35mm guide rail which is convenient and quick to install.

 

Q:Which signal input does DJSF1352-RN support?

A:DJSF1352-RN voltage supports 1000V input, current supports shunt (0-75mV), Hall sensor (0-20mA, 4-20mA, 0-5V) access.

 

Company Profile

Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function

Acrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.


Djsf1352-Rn DC Energy Meter Relay Alarm Output and Digital Input Function
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now