Amc96L-E4 Multifunction 3 Phase Power Meter for Telecom Tower

Product Details
Customization: Available
Communication: RS485 (Modbus-RTU)
Rated Current: AC 1A, 5A
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Arabic
Experienced Team
The supplier has 42 foreign trading staff(s) and 33 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (18)
  • Amc96L-E4 Multifunction 3 Phase Power Meter for Telecom Tower
  • Amc96L-E4 Multifunction 3 Phase Power Meter for Telecom Tower
  • Amc96L-E4 Multifunction 3 Phase Power Meter for Telecom Tower
  • Amc96L-E4 Multifunction 3 Phase Power Meter for Telecom Tower
  • Amc96L-E4 Multifunction 3 Phase Power Meter for Telecom Tower
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Front Panel
  • Wiring
  • Network
  • Installation
  • Company Profile
Overview

Basic Info.

Model NO.
AMC96L-E4
Accuracy
Active Energy: Class 0.5
Frequency
45-65Hz
Auxiliary Power Supply
AC/DC 85~265V
Transport Package
Carton
Trademark
Acrel
Origin
China
Production Capacity
200000 PCS/Yaer

Packaging & Delivery

Package Size
17.00cm * 15.00cm * 13.00cm
Package Gross Weight
0.500kg

Product Description

Product Description
Amc96L-E4 Multifunction 3 Phase Power Meter for Telecom Tower

AMC96L-E4/KC

True RMS Measurements

THD with 2-31st Harmonics

Max/Min Log with Timestamp

Internal Optional 4DI&2DO or 2DI&2DO&2AO

Standard one Energy Pulse Output


AMC96L-E4/KC 3 phase multi-function power meter adopts high-brightness LED/LCD display interface, and realizes parameter setting and control through buttons, which is very suitable for real-time power monitoring system. It can directly replace conventional power transmitters and measuring instruments. As an intelligent and digital front-end acquisition component, the instrument has been widely used in various control systems, SCADA systems and energy management systems.
Product Parameters
Function Description&Value
Measurement

Three-phase AC kWh, kVarh, Active Power, Reactive Power, Forward&Reverse Power, Current, Voltage, Zero Sequence Voltage, Zero sequence Current, Voltage-phase Angle, Voltage&Current Unbalance, Power Factor, Harmonic, Frequency

Display

LCD display

Communication(Optional)

RS485,Modbus-RTU protocol;(1 start bit,8 data bit,1 stop bit,no parity)

Baud Rate 1200~38400 bps etc.

Alarm Output(Optional)

1 channel passive relay,contact capacity 3A/30VDC,3A/250VAC,

Used for high, low, unbalanced alarms, etc.

Analog Output(Optional)

1~5V DC or 4~20mA DC

DI/DO Switching(Optional)

DI (Digital input): 2-channel or 4-channel dry contact digital input with built-in power supply

DO (Digital output): 2-channel digital output with NO relay contact. Capacity: 3A/30V DC,3A/250V AC

 
Parameter Description&Value
Input Rated Voltage AC Voltage Input: 400V or 660V AC L-L (via direct connetion); 100V AC L-L (via -/100V AC PTs)
Rated Current AC Current Input: 5A AC or 1A AC (via -/5A AC or -/1A AC CTs)
Overload

Current&Voltage input overload:1.2 times rated value(continuous); 10 times rated value /1 second

Frequency 45~65Hz
Power Consumption

The power consumption of each current&voltage input circuit is less than 0.5VA

Measuring Accuracy Voltage 0.2%
Current 0.2%
Active Power 0.5%
Reactive Power 1.0%
kWh 0.5%
kart 1.0%
Frequency ±0.05Hz
Harmonic ±1%
Power Supply Voltage Range 85-265V AC/DC; 24V or 48V DC (±20%)
Power Consumption

≤10VA

Insulation resistance

≥ 100MΩ

Power frequency withstands voltage

Between Power supply//Switching Output// Current Input//voltage Input and Transmitting// Communication //Pulse Output//switching input AC 2 kV 1min;

Between Power supply,switching output,Current Input,voltage Input AC 2 kV 1min;

Between Transmitting,Communication,Pulse Output,switching input AC 1kV 1 min;

Front Panel

Amc96L-E4 Multifunction 3 Phase Power Meter for Telecom Tower


LCD Display

Amc96L-E4 Multifunction 3 Phase Power Meter for Telecom Tower


Features of AMC96L-E4 3 Phase Multifunction Power Meter

1. It has RS485 communication interface, and adopts MODBUS-RTU protocol to meet the needs of communication network management;

2. The 4-20mA analog output can correspond to the measured electrical parameters and meet the interface requirements such as DCS;

3. With switch input and relay output, the function of "remote signal" and "remote control" of circuit breaker switch can be realized.

Wiring
Amc96L-E4 Multifunction 3 Phase Power Meter for Telecom TowerAmc96L-E4 Multifunction 3 Phase Power Meter for Telecom Tower
Network

Amc96L-E4 Multifunction 3 Phase Power Meter for Telecom Tower

 

Installation
 
Amc96L-E4 Multifunction 3 Phase Power Meter for Telecom Tower
 
Company Profile

Amc96L-E4 Multifunction 3 Phase Power Meter for Telecom Tower

 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now