Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower

Product Details
Customization: Available
Interface: RS485
Protocol: Yd/T1363.3-2014
Still deciding? Get samples of US$ 69/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Arabic
Experienced Team
The supplier has 42 foreign trading staff(s) and 33 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (17)
  • Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower
  • Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower
  • Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower
  • Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower
  • Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Wiring
  • Networking
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
AMC16L-DETT
Application
Telecom Base Station
Communication
RS485 (Modbus-RTU)
Transport Package
Carton
Specification
AMC16L-DETT
Trademark
Acrel
Origin
China
HS Code
9028301400
Production Capacity
200000

Packaging & Delivery

Package Size
17.00cm * 15.00cm * 13.00cm
Package Gross Weight
0.500kg

Product Description

 

Product Description

Base station DC energy meter AMC16L-DETT is specially designed for base stations. The meter could measure 6 circuits DC energy, and provide the power supply for the matched hall sensors. Meanwhile, it can realize zero drift calibration by upper computer software.It also has the functions of telemetering,teleindication,teleadjusting, metering at real time, energy quality abnormal alarm, data storage and processing, data interaction. This meter can measure DC power consumption of three operators, providing detail datas for base station.

Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower
 

DC rated Voltage: 1 channel: -48VDC
DC rated Current: 6 channels hall sensors - total 200A/5V
Active power,Voltage,Current,Power factor,Frequency
Communication: RS485 (Modbus-RTU)
LCD display
35mm DIN Rail Installation
Designed for base stations

 

Communication

Single Channel RS485 communication protocol standard or customized


 

Display

LCD indicator display


 

Rated U and I

Total 200A/5V

Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower

Features
 
1. AMC16-DETT Base Station 6 channel DC Energy Meter For telecom Tower can measure the DC electric energy of the six circuits, and can provide the working current for the matching Hall sensor;

2. AMC16-DETT Base Station 6 channel DC Energy Meter For telecom Tower can monitor equipment system time, total voltage, total output current, total power, total electric energy, and voltage, current, power and electric energy of each branch;

3. AMC16-DETT Base Station 6 channel DC Energy Meter For telecom Tower can have alarm function, LED indicator light display, RS485 communication,and support broadcasting for calibration time.
 

Specification

Technical parameter

Index

  

 

 

 

 

       input

DC rated voltage

1 channel: -48VDC

DC current

6 channels hall sensors output is 5V,current ratio can be set  according to the actual ratio

Commercial power

monitoring

1 channel: 0-5VDC

 

Overload capacity

Voltage:1.2times continued,2 times continued 1s;Current: 1.2 times continued,10 times continued 1s.
Accuracy (superposition hall sensors) 1%In≤I≤10%In error±2.5%; I>10%In error±2%
 Measurement resolution Voltage output accuracy 0.01V;    current output accuracy 0.01A;power output accuracy 0.01kw; energy output accuracy 0.01kwh.
  

 

 

 

 

 

 

 

 

functions

 Basic function Monitor device system time, total voltage, output total current, power, energy, each channel voltage, current, power, energy; LED indicator display;485 communication.
  

 

 

 

Metering function

Start current: under rated voltage, when the load current value of the meter doesn't exceed 1% of the max. current, the meter starts.Shunt running current: when there is no current in the current circuit of the meter, and 85%-125%of the rated voltage is applied on the voltage circuit, the calculator shall not have more than one digital change.
  

 

Alarm function

DC voltage output low alarm,DC voltage output high alarm,one power down alarm, module voltage loss alarm, metering branch error alarm, internal program error alarm, clock error alarm,memory failure alarm, AC input power failure alarm
 Timing function support broadcast timing, could remote timing to the meter through RS485 communication.
 Communication

Single channel RS485, baudrate 9600bps, can be set to 1200BPS, 2400bps, 4800bps.

Communication protocol: standard or custmized

 

  Hall sensor powersupply  Power supply output:+12V/100mA, -12V/50mA
Clock accuracy ≤0.5S/d(23ºC), ≤1S/d(-20ºC-60ºC),
Auxiliary powersupply Voltage range -40V~-60VDC
Power consumption Whole device≤2W( no hall power supply output)
 

 

Storage

It has the storage function of historical power data and historicalalarm information, and the memory is 2MB
Insulation resistance ≥40MΩ
 environment Temperature Working : -20ºC~+60ºC; storage:-40ºC~+70ºC
Humidity ≤98% no condensation, no corrosive gas place

Altitude

≤4000m

Protection level

IP20
 Material flame retardent Terminal glow wire temperature 960ºC±10ºC ,shell glow wiretemperature 650ºC±15ºC

installation

Standard 35mm din rail
 Lightning protection Voltage input(differential mode)  Peak value 5kA
Auxiliary power supply(differential mode)  Peak value 5kA

 
 

Wiring

Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower

Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower
 

 

FAQ


Q:The measurement of the metering module is inaccurate.
A:Check input whether the polarity and direction of the input voltage and current wiring are correct;Whether the direction of the primary current of the Hall sensor is correct; Whether the output signal of the Hall sensor matches the input signal required by the module; Check whether the output negative pole of the voltage output Hall sensor is connected to the module GND.
 
Q:Communication is abnormal.
A:Check communication whether the communication cable is normal; check whether the communication terminals A and B are staggered; check whether the address of the module is set correctly and whether the communication baud rate is set correctly; if the communication of multiple modules is not normal, first try whether the single-machine communication is normal.
 
Q:The metering module cannot be displayed normally.
A:Check whether it is caused by insufficient load capacity due to the built-in power supply to the hall sensor. Change the external switching power supply to power the hall.
 

Networking

Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower

 

Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower

Certifications

Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower

Company Profile

Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower

Acrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.
 

Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower
Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower
Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower
Amc16L-Dett Base Station DC Monitoring Energy Meter LCD Display for 5g Tower


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier