AC220V
3×1(6)A,3×10(80)A
RS485(MODBUS-RTU)
Set parameters
LCD display
kWh Class 0.5
DIN 35 mm
Acrel ADL400 three phase din rail energy meter is an intelligent instrument designed mainly for electric energy statistics and management needs of power systems, industrial and mining enterprises, and public facilities. The product has the advantages of high precision, small size, and convenient installation.
It can measure all power parameters, with 2~31 sub-harmonic and total harmonic content detection. With RS485 communication interface and optional MODBUS-RTU protocol, the power meter can be widely used in various control systems, SCADA systems, and energy management systems.
technical parameter descriptions | |||
project | performance parameter | ||
Specification | 3 phase 3 wires, 3 phase 4 wires | ||
Measurement | Voltage | Reference voltage | 3×100V, 3×380V,3×57.7/100V, 3×220/380V |
Consumption | <10VA(Single phase) | ||
Impedance | >2MΩ | ||
Accuracy class | Error±0.2% | ||
Current | Input current | 3×1(6)A, 3×10(80)A | |
Consumption | <1VA Single phase rated current | ||
Accuracy class | Error±0.2% | ||
Power | Active, reactive, apparent power, error±0.5℅ | ||
Frequency | 45~65Hz,Error±0.2% | ||
Meter | Energy | Active energy(Accuracy class: 0.5) reactive energy(Accuracy class 2) |
|
Clock | ≤0.5s/d | ||
Digit signal | Energy pulse output | 1 active photocoupler output | |
pulse | Width of pulse | 80±20ms | |
Pulse constant | 400imp/kWh,10000imp/kWh(Correspond with the basic current) | ||
communication | Interface and communication protocol | RS485:Modbus RTU | |
RS485:Modbus RTU | |||
Range of communication address | Modbus RTU:1~ 247; | ||
Baud rate | 1200bps~19200bps | ||
environment | working temperature | -25ºC~+55ºC | |
Relative humidity | ≤95℅(No condensation) |
3 phase 4 wire Secondary Accessing | 3 phase 4 wire Directly Accessing |
Benefits
Q: What's the difference of current input via direct connect or via CTs?
A: Normally, for 3-phase loads with rated current below 80A AC, we will use model of ADL400 whose current input is via direct connect. Specs of "Rated Current: 10(80)A AC" was aimed for this model of ADL400 (current input via direct connect). 10 means basic current is 10A AC, 80 means rated current input is 80A AC.
And for 3-phase loads with rated current over 80A AC, we will use model of ADL400 whose current input is via CTs (usually paired with -/5A CTs whose secondary current output is with 5A AC rated current output). Specs of "Rated Current: 1(6)A AC" was aimed for this model of ADL400 (current input via CTs). 1 means basic current is 1A AC, 6 means max current input is 6A AC.
Q: Do your company also have paired CTs for ADL400?
A: Usually, we will recommend our user to use split-core CTs called AKH-0.66/K K-φ Series or solid-core CTs called AKH-0.66/I Series to the paired with ADL400 (current input via CTs)
Q: How can I set the CT or PT ratio of ADL400?
A: Current ratio of ADL400 could be set by using the keypads on ADL400 and following the instruction of ADL400 manual. Also, setting need to be according to the CTs or PTs ratio which were paired with ADL400. For example, if the current input is via 250A/5A CTs, the CT ratio on ADL400 should be set to 250/5=50. And if the voltage input is via direct connect, PT ratio on ADL400 should be set to 1. When the problem hasn't been solved, please contact us for help.
Q: Could ADL400 be used in IoT Energy Monitoring System for factory or building?
A: ADL400 has standard RS485 interface and MODBUS-RTU communication protocol which allow it to be integrate with our IoT Energy Monitor Solution that can enable our users to remotely check all the data collect by energy meters like ADL400 on their mobile phone or PC. For more information, please Contact us or check in IoT Energy Monitoring Solution Introduction.