Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 52.5/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ADL100-EY single-phase pre-paid meters with intro-control are used for calculating the single-phase active energy respectively on the frequency of 50 Hz. The meter has functions of pre-paid, load control, RS485 communication, etc. meets the related technical requirements of electronic power meter in the IEC62053-21, IEC62053-22 standards.
ADL300-EY three-phase pre-paid meters with intro-control are used for calculating the three-phase active energy respectively on the frequency of 50 Hz. The meter has functions of pre-paid, load control, RS485 communication, etc. meets the related technical requirements of electronic power meter in the IEC62053-21, IEC62053-22 standards.
Technical parameters | ADL100-EY | ADL300-EY | |
Voltage | Nominal voltage | 220V | 3*220/380V |
Nominal frequency | 50/60Hz | ||
Consumption | <4VA(Each phase) | ||
Current | Maximum current | 60A | 6A,80A |
Starting current | Connect directly:0.04A,connect via CT:0.002A | ||
Consumption | <4VA(Maximum current) | ||
Measurement | Accuracy | Class 1 | Class 0.5s |
performance | |||
Clock | Accuracy | Error ≤0.5 | |
Active pulse | Width | 80ms±20ms | |
Constant | 1600imp/kWh | 6400imp/kWh | |
Communication | Interface | RS485 | |
Protocol | MODBUS-RTU | ||
Temperature range | Operating | -25ºC ~55ºC | |
Storage | -40ºC ~70ºC | ||
Humidity | ≤95%(No condensation) | ||
Altitude | ≤2000m |
ADF400L |
Parameter | Description & Value | |
Auxiliary
Power Supply
|
Voltage |
3*220V/380V (for 3-phase sub-modules); 220V AC (for 1-phase submodule) |
Power Consumption |
≤10W |
|
Input
Voltage
|
Rated Voltage | 3x 220/380V AC (3-phase); 220V AC(1-phase) |
Frequency | 50Hz | |
Input
Current
|
Rated Current | Max 80A Load Current (for 1-phase&3-phase sub-module with direct connection); 3×1(6)A(for 3-phase sub-module via CTs) |
Starting Current | 1‰ Ib (Class 0.5S) | |
Accuracy
|
Measurement | Class 0.5 |
Clock | ≤0.5s/d | |
Pulse
|
Pulse Output | 1 Active Energy Pulse for each 3-phase Sub Module |
Pulse Width | 80ms±20ms | |
Pulse Constant | 6400imp/kWh (3-phase) | |
Communication
|
RS485 | MODBUS-RTU |
Infrared | For Prepaid Card Scanning | |
Ethernet | MODBUS-TCP | |
Environment
|
Operating Temperature | -20ºC~+60ºC |
Storage Temperature | -30ºC~+70ºC | |
Humidity | ≤95% (No condensation) | |
Altitude | <2000m |