Customization: | Available |
---|---|
Type: | Hall Type |
Output Signal Type: | Analog Output |
Still deciding? Get samples of US$ 10/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment methods: | |
---|---|
Support payment in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Rated current input: 0~(50-5000)A
Rated output: 5V / 4V / 4-20mA
Aperture: 20mm/40mm/55mm/etc
Power supply: ±15V / 12V / 24V
Small package size
Low power consumption
Extended measuring range
Split Type; Easy installation
Enter | Description&Value |
Rated Input
|
0~±(50-500)A DC or 0~(50~500)A AC |
Rated Output
|
±5Vdc/±4Vdc |
Accuracy
|
Class 1.0 |
Power Supply
|
±15Vdc (allow ±20% fluctuation%) |
Consumption
|
≤0.5W |
Zero Offset Voltage
|
±20mV |
Offset Voltage Drift
|
≤±1.0mV/ºC |
Linearity
|
≤0.2%FS |
Response Time
|
≤5us |
Bandwidth
|
0~20kHz |
Isolation Voltage
|
3.5kV/50Hz/1min |
Condition | Description&Value |
Temperature |
Operating Temperature: -40ºC~+85ºC; Storage Temperature: -40°C ~+85°C |
Humidity |
≤95%RH, no condensation, without corrosive gas |
Altitude | ≤ 2000m |
Notes:
1. When the hall sensor is used, in order to obtain better dynamic characteristics and sensitivity, attention must be paid to the coupling between the primary side coil and the secondary side coil. It is recommended to use a single wire and the wire completely fills the hall sensor module wire hole;
2. When the hall sensor is used, the best measurement accuracy can be obtained under the rated input current value. When the measured current is far lower than the rated current To obtain the best accuracy, multiple turns can be used for the primary side, i.e. IPNP = rated ampere turns. In addition, the temperature of the primary side feeder shall not exceed 80 ºC;
3. The auxiliary power supply of Hall current sensor shall not exceed ± 20% of the calibrated value when it works normally;
4.Hall current sensor shall not fall from a high place (≥ 1m) during installation and use;
5. It is unable to adjust the zero point and full degree adjustment potentiometer;
6. Auxiliary power supply needs to be configured by itself;
7. The positive and negative poles of the power supply cannot be reversed.