Customization: | Available |
---|---|
Certification: | CE |
Protection: | Shock Resistance |
Still deciding? Get samples of US$ 145.38/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ALP series intelligent low-voltage line protectors are suitable for low-voltage systems with rated voltages up to AC 400V, rated currents up to AC 6300A, and rated frequencies of 50/60Hz. The product integrates protection, measurement, control, and bus communication. It also provides functions such as remote automatic control, on-site direct control, panel instructions, signal alarms, operation records, trip alarm records, and switch value records.
As a new intelligent integrated device for the protection, monitoring, and control of low-voltage feeder terminals, the product is suitable for coal mines, petrochemicals, smelting, electric power, ships, and civil buildings.
Function | ALP200 | ALP220 | ALP320 | ALP220-PT |
Application occasions | 0.4KV Feeder | 0.4KV Feeder | 0.4KV Feeder | 0.4KV PT |
Switch value acquisition | 5 | 5 | 9 | 5 |
Relay output | 4 | 4 | 5 | 4 |
Measure | I | U, I, P, PF, F, KWh | U, MAXu, Uo, F, εμ | |
Inverse time overcurrent protection | YES | YES | YES | |
Low definite time overcurrent protection | YES | YES | YES | |
High definite time overcurrent protection | YES | YES | YES | |
Low definite zero sequence protection | YES | YES | YES | |
High definite zero sequence protection | YES | YES | YES | |
Inverse time zero sequence protection | YES | YES | YES | |
Phase failure protection | YES | YES | YES | |
Unbalance protection | YES | YES | YES | |
Current demand protection | YES | YES | YES | |
Linkage 1 protection | YES | YES | YES | YES |
Linkage 2 protection | YES | YES | YES | YES |
Linkage 3 protection | YES | YES | YES | YES |
Undervoltage protection | YES | YES | ||
Overvoltage protection | YES | YES | YES | |
Residual current protection | Optional | Optional | Optional | |
Low voltage one-stage protection | YES | |||
Low voltage two-stage protection | YES | |||
Low voltage three-stage protection | YES | |||
Zero sequence overvoltage protection | YES | |||
Voltage unbalance protection | YES | |||
PT disconnection protection | YES | |||
Trolley position protection | YES | |||
Communication Modbus-RTU | YES | YES | YES | YES |
One 4-20mA analog output | YES | YES | YES | YES |
8 fault records | YES | YES | YES | |
8 opening records | YES | YES | YES | |
8 closing records | YES | YES | YES | |
8 DI action records | YES | YES | YES | |
Protection query | YES | YES | YES | YES |
Protection setting | YES | YES | YES | YES |