• 10kv Substation Power System Protection Device
  • 10kv Substation Power System Protection Device
  • 10kv Substation Power System Protection Device

10kv Substation Power System Protection Device

Type: Power
Structure: Protection
Certification: ISO9001:2000
Form: All- packaged Type
Operation Voltage: High Voltage
Size: 1 Uint
Samples:
US$ 777/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
  • Overview
  • Product Parameters
  • Panel
  • Dimension
  • Display
  • Wiring
  • Networking
  • FAQ
  • Related Products
Overview

Basic Info.

Model NO.
AM4
Application Range
Substation
Shell Material
Plastic
Shell Protection Grade
IP30
Brand
Acrel
Function 1
Voltage Protection
Function 2
Current Protection
Transport Package
Carton
Specification
AM4
Trademark
Acrel
Origin
China
HS Code
8536300000
Production Capacity
200000

Product Description

AM4 series protection relay is applicable to the user substation which the input voltage is 35kv and below. We adopt mature technology solutions to ensure the quality of the AM relay. The AM relay is widely used in substations, subsection posts and ring main units for office buildings, commercial buildings, communication buildings, mine buildings, and so on.

 

Product Parameters

 
Rated Parameter Power Supply Power supply: AC/DC220V, or AC/DC110V, or DC48V(Reference the wiring diagram)
Range: Power supply x (1±20%)
Maximum power consumption:≤10W(DC)
Rated Voltage Rated Voltage: AC100V
Range:1-120V
Accuracy:±0.5%
Power Consumption:≤0.5VA(Single phase)
Overload capacity:1.2 times rated voltage for continuous work;2 times for 10 seconds
Rated Current Rated current: AC 5A/1A(See the device wiring diagram)
Range:0.04In~15In
Power consumption:≤0.5VA(Single phase)
Over capacity:2 times rated current for continuous work;40 times for 1 second
Frequency Rated frequency:50Hz or 60 Hz
Range:45~55Hz
Accuracy:±0.1Hz
Digital Input Rated Voltage: AC/DC220V, AC/DC110V, DC48V(Similar to the power supply)
Voltage Range: Rated voltage x (1±20%)
Power Consumption:≤1W(DC220V)(Single channel)
Digital Output Mechanical life:≥10000 times
Switching capacity:≥1000W, L/R=40ms
On current:continuous≥5A short time(200ms)≥30A
Interrupting capacity:≥30W,L/R=40ms
Normal Working Conditions Ambient temperature:-10ºC~+55ºC
Device storage, transport allows the ambient temperature is -25ºC~+70ºC
Relative humidity:5%~95%(The product does
Altitude:≤4000m
Function Current Type Voltage Type
AM4-I AM4-U1
Current collection 4 0
Voltage collection 4 4
Switch value collection 12 12
Relay output 5 5
Protection Function
Overcurrent (three stages, inverse time limit)  
Zero sequence overcurrent (two stages, inverse time limit)  
Negative sequence overcurrent (two stages, inverse time limit)  
Reclosing  
Overload trip/alarm  
Low-frequency load shedding  
After accelerating overcurrent  
Overvoltage trip  
Low voltage trip  
FC blocking  
Control failure alarm  
Non-electricity trip/alarm  
Low voltage alarm
Overvoltage alarm
Zero sequence overvoltage alarm (self-produced/external)
PT disconnection alarm
Self-produced zero-sequence overvoltage alarm  
Communication protocol
Modbus-RTU
IEC60870-5-103
Auxiliary function
Fault recording  

Panel

10kv Substation Power System Protection Device

Dimension

10kv Substation Power System Protection Device

Display

10kv Substation Power System Protection Device

Wiring

10kv Substation Power System Protection Device

Networking

 

10kv Substation Power System Protection Device

FAQ

Q: How to set the CT and PT ratio of the protection device?

A: The protection device can set the CT and PT ratio through the fixed value menu. For example, the current transformer is 75/5 and the voltage transformer is 10/0.1, then the CT ratio is set to 15 and the PT ratio is set to 100.


Q: For AM5, if you want to place single circuit protection and transformer protection, how to distinguish the model?

A: AM5-F is suitable for line protection and transformer protection.No need to distinguish between models when placing orders


Q: When the voltage is a three-phase three-wire system, does the current have to be connected with 2CT?

A: The voltage wiring mode and current wiring mode of the protection device can be set independently, and can be connected freely.


Q: How to confirm whether the anti-trip function is configured?

A: If the circuit breaker is equipped with anti-trip, the device does not must be equipped with anti-trip; if the circuit
breaker does not have anti-trip, you need to configure the AM5-FT anti-trip module. (If DC48V is selected as the
operating power supply, the anti-trip box is not optional, and the circuit breaker must be equipped with anti-trip
function; if you choose AC anti-trip, please note that AC and DC general anti-tripping)


Q: How to purchase suitable protection devices?

A: Before ordering, it is recommended to consult related engineers, select the appropriate protection model,
and then fill in the corresponding selection table, and place the order after confirmation by the engineers.

Related Products

Specification AM2SE AM3SE AM4 AM5 AM5SE
Hardware Protect Current 3 channels 3 channels 3 channels 3 channels 3 channels
Measure Current × × × 3 channels 3 channels
zero-sequence current 1 channel 2 channels 1 channel 2 channels 2 channels
Measure Voltage 3 channels 3 channels 4 channels 4 channels 4 channels+ backup 2 channels
Switch Value Input 8 channels 11 channels 12 channels 16 channels 20 channels
Switch Value Output 5 channels 5 channels 5 channels 10 channels 10 channels
RS485 Interface 1 channels 1 channel 1 channel 2 channels 2 channels
RS232 Interface × × 1 1 1
USB ×
CE × optional 2
GPS time synchronization × ×
4-20mA × optional 2
Anti-jump Optional external anti-hop module built-in
operation circuit ×
Protection Main transformer differential protection × × × ×
Main transformer backup protection × × × ×
Three-stage overcurrent
With direction with a voltage blocking
× × ×
Three-stage overcurrent
with directional locking
×
Three-stage overcurrent
Zero sequence overcurrent protection
Overvoltage protection
Low voltage protection
Zero sequence overvoltage protection
High-power motor differential protection
(>2000KW)
× × × ×
High Voltage Motor Protection × × ×
Capacitor Protection × × ×
Overcurrent after acceleration
Low-frequency load shedding
Grid-connected reverse power protection × × ×
PT disconnection alarm
Fault alarm
FC blocking
Incoming line of high voltage single busbar system
/Mother-joint prepared self-injection
× × ×
Low-voltage standby self-switching(400V) × × × ×
PT monitoring and parallel functions × × × ×
PT monitoring functions
Non-electrical protection
(temperature, gas, etc.)
Synchronization function × × × ×
Fault recorder
Electrical parameter measurement U, I, Fr, P, Q, PF, Ep, Eq, Es

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
Registered Capital
10000000 RMB
Plant Area
>2000 square meters