After-sales Service: | Yes |
---|---|
Warranty: | 2 Years |
Display: | Digital |
Installation: | Direct Connected |
Usage: | Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter |
Electric Equipment: | Single-phase |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
DTSD1352 3 phase smart power meters for Solar Inverter
DTSD1352-C Solar inverter smart meter is designed for PV solar system, which already have configued with several inverter like sungrow, solis etc. It can be directly used together with these inverter through RS485 communication. realize the measure and monitor function.
Specification | 3 phase 3 wires, 3 phase 4 wires | |
Voltage |
Reference voltage |
3×100V, 3×380V,3×57.7/100V, 3×220/380V |
Consumption |
<10VA(Single phase) | |
Impedance |
>2MΩ | |
Accuracy class |
Error±0.2% | |
Current |
Input current |
3×1(6)A,3×1(6)A(Outlay transformer),3×10(80)A,3×10(100)A(Outlay transformer) |
Consumption |
<1VA(Single phase rated current) | |
Accuracy class |
Error±0.2% | |
Power |
Active, reactive, apparent power, error±0.5℅ | |
Frequency | 45~65Hz, Error±0.2% | |
Temperature | -40ºC~99ºC | |
Energy |
Active energy(Accuracy class:0.5, 1), reactive energy(Accuracy class 2) | |
Clock |
≤0.5s/d | |
Energy pulse output | 1 active optocoupler output, 1 reactive optocoupler output | |
Switching output | 1 Switching output, Maximum allowed voltage: DC/AC 220V | |
Switching input | 1 optocoupler input,Maximum allowed voltage: DC/AC 220V | |
Width of pulse |
80±20ms | |
Pulse constant |
6400imp/kWh,400imp/kWh(Correspond with the basic current) | |
Interface and communication |
RS485:Modbus RTU | |
Range of communication address |
Modbus RTU:1~ 247; | |
Baud rate |
1200bps~19200bps | |
Relative temperature |
-25ºC~+55ºC | |
Relative humidity |
≤95℅(No condensation) |
DTSD1352-4S Matching current transformers
Type | Ratio | Line Length | Accuracy | Installation Method |
AKH-0.66/W-12NY 100A/50mA | 100A/50mA | (1+0.2)m | 0.2 class | Closed type, crystal head interface |
AKH-0.66/K-16N 100A/50mA | 100A/50mA | (1+0.2))m | 0.5 class | Open type, crystal head interface |
AKH-0.66/W-20Y 200A/50mA | 200A/50mA | (1+0.5)m | 0.2 class | Closed type, crystal head interface |
AKH-0.66/K-24N 200A/50mA | 200A/50mA | (1+0.5)m | 0.5 class | Open type, crystal head interface |
AKH-0.66/W-30NY 250A/50mA | l250A/50mA | (1+0.5)m | 0.2 class | Closed type, crystal head interface |
AKH-0.66/K-24N 250A/50mA | l250A/50mA | (1+0.5))m | 0.5 class | Open type, crystal head interface |
AKH-0.66-TD-OD60-NY | 400A/50mA | (1+0.5)m | 0.2 class | Closed type, crystal head interface |
Acrel DTSD1352-C Solar Inverter Smart Meter Application
1. Connected to solar inverter in PV solar system
2. Industrial and mining enterprises's kwh meausrenment.
3. Calculate the electricity consumption in power supply system
4. Measurement of electrical energy in large public buildings