Customization: | Available |
---|---|
Installation: | DIN Rail 35mm |
Dimension(L*W*H): | 180*94.3*75mm |
Still deciding? Get samples of US$ 176.9/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Function | Description |
Measurement (Common) |
AC kWh, kVarh, Active Power, Reactive Power, Current, Voltage, Power Factor, Apparent Power, Frequency, Zero ground voltage, neutral line current |
Measurement (Power Quality) |
total harmonic content (THD), 2-31 harmonics |
Temp.&Humidity Monitoring | Temperature Monitoring Range: -40ºC~+99ºC |
Humidity Monitoring Range: 20%~90% | |
Accuracy | Voltage/current/active power/active energy level 0.5, reactive power/reactive energy level 1 |
Communication | RS485 Interface (MODBUS-RTU protocol) |
DI (Switch Input) |
48-channel DI (Digital Input); dry contact |
With the rapid development of data center, the energy consumption problem of data center is becomingmoreand more prominent. The energy management and power supply and distribution design of data center havebecomeahot issue. Efficient and reliable power distribution system scheme of data center is an effective way toimprovethepower consumption efficiency of data center and reduce the energy consumption of equipment. In order torealizeenergy saving in data center, it is necessary to monitor each electrical load first. However, there aremanyloadcircuits in data center. Traditional measuring instruments cannot meet the requirements of cost, volume, installation,construction and other aspects. In this case, the multi-circuit monitoring device which is suitable for centralizedmonitoring in data center is necessary to be used.
AMC16Z series AC precision power distribution monitoring device is specially designed for data centerserverpower management.The device designed exquisite, can provide A + B 2 incoming and 96 outgoingelectricalparameters, the input and output switch and the state of lightning protection device with real-time monitoring. Allalarm threshold of measurement channels can be set in separate. Over-outgoing triggers systemacoustoopticwarningimmediately. Highly integrated monitoring loop is realized in the volume of traditional instruments.
Distribution system | AC | |
Specification | 1 phase 2 wires, 3phase 4 wires | |
Measurement of electrical parameters | I,U,P,Q,EP,EQ,S | |
2~31st harmonic | ||
24 channels on each side(48 in total) | ||
48DI | ||
Voltage | Rated voltage | 3*220/380V |
Accuracy | ±0.2% | |
Current | CT | xxA/50mA |
Accuracy | ±0.2% | |
Auxiliary power supply | DC 12V | |
Power consumption | 3W | |
Frequency | 45~65Hz,±0.2% | |
Accuracy | Class 0.5(P/EP),Class 1(Q/EQ) | |
Communication | RS485(Modbus-RTU) | |
Temperature | Operating | -15~55ºC |
Storing | -25~70ºC | |
Humidity |
<95%(No condensation) |
|
Altitude | <2000m |
* 24 channels of each circuit of A+B
*independent 2 circuits the outgoing current,
*active power, active power, reactive power
DIN rail 35mm
* Dimension(L*W*H):
180*94.3*75mm
Cabinet Diagram