Overcurrent Protection Relays for Electrical Power System

Jiangsu Acrel Electrical Manufacturing Co., Ltd.
  • Audited Supplier
  • 7 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Comprehensive Protection Functions: Supports overcurrent, overload, zero-sequence, and reverse power protection for diverse applications.
  • Wide Application Range: Suitable for power, water, traffic, oil, chemical, coal, and metallurgical industries.
  • Flexible Customization Options: Offers full, minor, and flexible customization based on samples or designs.
  • High Reliability Certification: Certified with ISO9001:2000 and CCC standards for quality assurance.
  • Advanced Communication Protocols: Compatible with ModBus-RTU and IEC60870-5-103 for seamless networking.
  • Low Minimum Order Quantity: Accepts orders starting from just 1 piece for flexible purchasing.
  • Fast Lead Time: Production completed within 15 working days during peak or off-peak seasons.
  • OEM and ODM Services: Full support for OEM and ODM services with 32 dedicated R&D engineers.

Product Images of Overcurrent Protection Relays for Electrical Power System

Overcurrent Protection Relays for Electrical Power System
Overcurrent Protection Relays for Electrical Power System pictures & photos
Overcurrent Protection Relays for Electrical Power System
Overcurrent Protection Relays for Electrical Power System pictures & photos
Overcurrent Protection Relays for Electrical Power System
Overcurrent Protection Relays for Electrical Power System pictures & photos
Overcurrent Protection Relays for Electrical Power System
Overcurrent Protection Relays for Electrical Power System pictures & photos
Overcurrent Protection Relays for Electrical Power System
Overcurrent Protection Relays for Electrical Power System pictures & photos
Overcurrent Protection Relays for Electrical Power System
Overcurrent Protection Relays for Electrical Power System pictures & photos
Overcurrent Protection Relays for Electrical Power System
  • Overcurrent Protection Relays for Electrical Power System
  • Overcurrent Protection Relays for Electrical Power System
    Overcurrent Protection Relays for Electrical Power System
  • Overcurrent Protection Relays for Electrical Power System
    Overcurrent Protection Relays for Electrical Power System
  • Overcurrent Protection Relays for Electrical Power System
    Overcurrent Protection Relays for Electrical Power System
  • Overcurrent Protection Relays for Electrical Power System
    Overcurrent Protection Relays for Electrical Power System
  • Overcurrent Protection Relays for Electrical Power System
    Overcurrent Protection Relays for Electrical Power System
  • Overcurrent Protection Relays for Electrical Power System
    Overcurrent Protection Relays for Electrical Power System

Find Similar Products

Product Description

Overcurrent Protection Relays for Electrical Power System
AM5 series microcomputer protection devices are applicable to the user substation in which the input voltage is 35kv or above. AM5 can be used to protect and control the user substation and is being widely used in Power Industry, Water conservancy industry, Traffic Industry, Oil industry, Chemical industry, Coal Industry, Metallurgical Industry, and so on.

Overcurrent Protection Relays for Electrical Power System

Product Parameters

Function Specification
-F -C -M -T -B -U1 -DB
Hardware
Resource
Current acquisition 8 8 8 8 6 0 6
Voltage acquisition 4 4 4 4 6 4 6
Switch Collection 16 16 16 16 16 16 16
Relay Output 10 10 10 10 10 10 10
Protection Three-stage overcurrent protection √     √      
Three-stage overcurrent with direction blocking √            
Two-stage overcurrent protection   √ √   √   √
Zero-sequence overcurrent protection √ √ √ √      
Inverse time overcurrent protection √ √ √ √ √    
Overload protection √   √ √      
Control circuit disconnection alarm √ √ √ √ √   √
Under-voltage protection     √     √alarm  
Lack of voltage protection √            
PT disconnection alarm √ √ √ √ √ √ √
Three-phase one-time reclosing √            
Low-frequency load shedding √            
High-frequency protection √            
After accelerating overcurrent √       √   √
Overvoltage protection √ √ √     √alarm √alarm
Locked-rotor protection              
Undervoltage protection   √          
Unbalanced voltage protection   √ √        
Unbalanced current protection   √ √        
Phase error protection     √        
Zero sequence overvoltage protection √ √ √     √alarm  
Non-electric protection √ √ √ √      
Starting over time     √        
Reverse power protection √            
Thermal overload protection     √        
Negative sequence overcurrent
(two stages / inverse time limit)
    √        
Incoming line / busbar         √   √
Busbar charging protection         √    
FC blocking √ √ √ √      
Second harmonic blocking √ √ √ √      
Intermittent ground protection √ √          
Overhaul status lockout √ √ √ √ √ √ √
Communication protocol ModBus-RTU √ √ √ √ √ √ √
IEC60870-5-103 √ √ √ √ √ √ √
Accessibility Fault recorder √ √ √ √ √   √
IRIG-B time synchronization √ √ √ √ √ √ √

 

 

Overcurrent Protection Relays for Electrical Power System

Dimension

Overcurrent Protection Relays for Electrical Power System

 

Display

Overcurrent Protection Relays for Electrical Power System

Wiring

Overcurrent Protection Relays for Electrical Power System

 

Networking

Overcurrent Protection Relays for Electrical Power System

FAQ

Q: How to set the CT and PT ratio of the protection device?

A: The protection device can set the CT and PT ratio through the fixed value menu. For example, if the current transformer is 75/5 and the voltage transformer is 10/0.1, then the CT ratio is set to 15 and the PT ratio is set to 100.


Q: For AM5, if you want to place single circuit protection and transformer protection, how to distinguish the model?

A: AM5-F is suitable for line protection and transformer protection.No need to distinguish between models when placing orders


Q: When the voltage is a three-phase three-wire system, does the current have to be connected with 2CT?

A: The voltage wiring mode and current wiring mode of the protection device can be set independently, and can be connected freely.


Q: How to confirm whether the anti-trip function is configured?

A: If the circuit breaker is equipped with anti-trip, the device does not must be equipped with anti-trip; if the circuit
breaker does not have anti-trip, you need to configure the AM5-FT anti-trip module. (If DC48V is selected as the
operating power supply, the anti-trip box is not optional, and the circuit breaker must be equipped with anti-trip
function; if you choose AC anti-trip, please note that AC and DC general anti-tripping)


Q: How to purchase suitable protection devices?

A: Before ordering, it is recommended to consult related engineers, select the appropriate protection model,
and then fill in the corresponding selection table, and place the order after confirmation by the engineers.

Related Products

Specification AM2SE AM3SE AM4 AM5 AM5SE
Hardware Protect Current 3 channels 3 channels 3 channels 3 channels 3 channels
Measure Current × × × 3 channels 3 channels
zero-sequence current 1 channel 2 channels 1 channel 2 channels 2 channels
Measure Voltage 3 channels 3 channels 4 channels 4 channels 4 channels+ backup 2 channels
Switch Value Input 8 channels 11 channels 12 channels 16 channels 20 channels
Switch Value Output 5 channels 5 channels 5 channels 10 channels 10 channels
RS485 Interface 1 channel 1 channel 1 channel 2 channels 2 channels
RS232 Interface × × 1 1 1
USB × √
CE × optional 2
GPS time synchronization × √ × √ √
4-20mA × optional 2
Anti-jump Optional external anti-hop module built-in
operation circuit × √
Protection Main transformer differential protection × × × × √
Main transformer backup protection × × × × √
Three-stage overcurrent
With direction with a voltage blocking
× × × √ √
Three-stage overcurrent
with directional locking
× √ √ √ √
Three-stage overcurrent √ √ √ √ √
Zero sequence overcurrent protection √ √ √ √ √
Overvoltage protection √ √ √ √ √
Low voltage protection √ √ √ √ √
Zero sequence overvoltage protection √ √ √ √ √
High-power motor differential protection
(>2000KW)
× × × × √
High Voltage Motor Protection × × × √ √
Capacitor Protection × × × √ √
Overcurrent after acceleration √ √ √ √ √
Low-frequency load shedding √ √ √ √ √
Grid-connected reverse power protection × × × √ √
PT disconnection alarm √ √ √ √ √
Fault alarm √ √ √ √ √
FC blocking √ √ √ √ √
Incoming line of high voltage single busbar system
/Mother-joint prepared self-injection
× × × √ √
Low-voltage standby self-switching(400V) × × × √ ×
PT monitoring and parallel functions × × × × √
PT monitoring functions √ √ √ √ √
Non-electrical protection
(temperature, gas, etc.)
√ √ √ √ √
Synchronization function × × × × √
Fault recorder √ √ √ √ √
Electrical parameter measurement U, I, Fr, P, Q, PF, Ep, Eq, Es

Company Profile

Overcurrent Protection Relays for Electrical Power System

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR2541377". Items marked "verified" are certified.

Watch Video
Watch Video
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
No. 5, Dongmeng Road, Dongmeng Industrial Park, Nanzha Street, Jiangyin City, Wuxi, Jiangsu, China
verified Number of Employees
307
verified Registered Capital
326,860,200 RMB
verified Terms of Payment
LC, T/T, PayPal, D/P, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shanghai Port
verified Minimum Order Quantity
1 PC
verified Supply Chain Partners
164

Our Production Capability & Technical Expertise

Main Products
Power Meter, Energy Meter, WiFi Meter, RS485 Modbus-RTU Meter, Multifunction Relay, Motor Protection Relay, Busbar Temperature Sensor, Power Tag, Insulation Monitor, Current Sensor
verified Production Lines
3
verified Production Machines
SMT Line, Assembling Line, Auto Processing Line
verified QA/QC inspectors
24 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
32 people
verified Traceability of Raw Materials
Yes
verified Test Reports for Raw Materials
UL, Others

Our Industry Experience & Global Business Record

verified Year of Establishment
2004-12-14
verified Export Year
8 Years
verified Main Markets
North America, Europe, Southeast Asia/ Mideast
verified Repeat Buyers Choice
80%~100%
verified Number of Foreign Trading Staff
18
verified Overseas Agent/Branch
Yes
verified New Products Launched in Last year
Yes

FAQ

How to set the CT and PT ratio of the protection device?
The protection device can set the CT and PT ratio through the fixed value menu. For example, if the current transformer is 75/5 and the voltage transformer is 10/0.1, then the CT ratio is set to 15 and the PT ratio is set to 100.
For AM5, if you want to place single circuit protection and transformer protection, how to distinguish the model?
AM5-F is suitable for line protection and transformer protection. No need to distinguish between models when placing orders.
When the voltage is a three-phase three-wire system, does the current have to be connected with 2CT?
The voltage wiring mode and current wiring mode of the protection device can be set independently, and can be connected freely.
How to confirm whether the anti-trip function is configured?
If the circuit breaker is equipped with anti-trip, the device does not must be equipped with anti-trip; if the circuit breaker does not have anti-trip, you need to configure the AM5-FT anti-trip module. (If DC48V is selected as the operating power supply, the anti-trip box is not optional, and the circuit breaker must be equipped with anti-trip function; if you choose AC anti-trip, please note that AC and DC general anti-tripping)
How to purchase suitable protection devices?
Before ordering, it is recommended to consult related engineers, select the appropriate protection model, and then fill in the corresponding selection table, and place the order after confirmation by the engineers.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

People who viewed this also viewed