Branch Circuit Power Monitor Meter in IDC Head Cabinet for Pue

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Years
Still deciding? Get samples of US$ 91/Piece
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Arabic
Experienced Team
The supplier has 42 foreign trading staff(s) and 33 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (18)
  • Branch Circuit Power Monitor Meter in IDC Head Cabinet for Pue
  • Branch Circuit Power Monitor Meter in IDC Head Cabinet for Pue
  • Branch Circuit Power Monitor Meter in IDC Head Cabinet for Pue
  • Branch Circuit Power Monitor Meter in IDC Head Cabinet for Pue
  • Branch Circuit Power Monitor Meter in IDC Head Cabinet for Pue
  • Branch Circuit Power Monitor Meter in IDC Head Cabinet for Pue
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Module
  • Networking
  • Installation Instructions
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
AMC16Z
Installation
Direct Connected
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter
Electric Equipment
Three-phase Three-wire
Theory
Static Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Power Meter
Certification
CE
Customized
Customized
Channels
2, 24, 48
Measure
AC or DC
Communication
RS485, Modbus-RTU
Install
Dinrail
Standard
IEC61010-1, IEC62053-22
Transport Package
Carton
Specification
AMC16Z
Trademark
Acrel
Origin
China
HS Code
9028301400
Production Capacity
200000

Product Description

Product Description

With the rapid development of data centers, the energy consumption of data centers has become more and more prominent, and the energy management and power supply and distribution design of data centers have become hot issues.
An efficient and reliable data center power distribution system solution is an effective way to improve the Power Usage Effectiveness (PUE) of the data center and reduce the energy consumption of equipment.
The AMC series precision power distribution monitoring solution is a complete solution designed for the power distribution monitoring requirements of the column head cabinet in the Internet Data Center (IDC).

Product Parameters

 

Parameter AMC16Z-ZA AMC16Z-FAK24/48 AMC16Z-ZD AMC16Z-FDK24/48 AMC16Z-KD
Phase AC DC AC/DC
Channel 2 24/48 2 24/48 48
Measure U, I, P, Q, S, F, PF, EP, EQ,  U, I, P, E /
Neutral ground voltageNeutral currentTotal Harmonic content, 2-63rd Harmonic, Voltage phase sequence 2-63rd Harmonic
Bus Voltage Rated Input 220V AC 48V DC, 240V DC, 336V DC
Measure Range 85-280V AC ±20%
Overload Instantaneous voltage 2 times/sec
Current Loop Rated Input 5A 50mA 5V
Overload Continuous current 1.2 times, Instantaneous current 10 times/second
Frequency 45-6Hz /
Accuracy U, I: 0.2
EP: 0.5
EQ: 1
U, I: 0.5
E: 1
Auxiliary Power signal power(≤15W) 12-24V DC signal power(≤15W) 12-24V DC 12-24V DC
Insulation resistance 100MΩ
Power frequency withstand voltage Power/Input Signal between ports AC 2KV/1min 50Hz
Environment Temperature Working: -15ºC~55ºC  Storage: -25ºC~70ºC
Humidity Relative humidity ≤ 93%
Altitude ≤ 2500m
Switch Value Output 2 channels
3A 250VAC / 3A 30VDC
/ 2 channels
3A 250VAC / 3A 30VDC
/ /
Switch Value Input 6 dry contacts 24 / 48 -way wet contact 6 dry contacts 24 / 48 -way wet contact 48 dry contacts
Communication RS485  Modbus-RTU
Installation Din-rail or Wall-mounted
Protection level IP20
Pollution level 2
Safety Insulation The insulation resistance between all terminals and the conductive parts of the housing is not less than 100MΩ
Pressure resistance Signal input, relay output, rs485 communication/leakage/temperature/humidity/auxiliary power supply/switch input together, AC2KV/1min, leakage current less than 2mA, no breakdown, and flashover
Electromagnetic Compatibility Anti-static interference 4 grade
Immunity to fast transient bursts 3 grade
Anti-surge interference 4 grade
Resistant to radiofrequency electromagnetic field radiation 3 grade

Module

AC
Branch Circuit Power Monitor Meter in IDC Head Cabinet for Pue
AMC16Z-ZA

A+B independent 2-way:
three-phase busbar incoming voltage, current, active power, reactive power,
power factor, active energy, reactive energy, 2-63 harmonics,
neutral current, neutral voltage,
6DI2DO, 2-way leakage, 1-way temperature and humidity,
1 channel RS485 communication,
Comes with DC24V voltage output, giving points
circuit module and touch screen power supply
AMC16Z-FAK 24/48

A+B independent 2-way:
Three-phase outgoing line voltage, 12 on each side
or 24 single-phase current, active power,
reactive power, power factor, active energy, reactive energy, 2-31 harmonics,
24/48 active switch inputs, 1 RS485 communication
Branch Circuit Power Monitor Meter in IDC Head Cabinet for Pue

DC

Branch Circuit Power Monitor Meter in IDC Head Cabinet for Pue
AMC16Z-ZD

A+B independent 2-way:
The busbar incoming voltage, current,
power, active energy,
6DI2DO, 1 channel temperature and humidity,
1 channel RS485 communication,
Comes with DC24V voltage output,
to branch module and touch screen power supply
With 2 channels of ±12V voltage output, to the main
Road Hall sensor power supply
 
AMC16Z-FDK 24/48

A+B independent 2-way:
Outgoing line voltage,
12 on each side or 24 channels current, power, energy,
24/48 active switch inputs,
1 RS485 communication
Branch Circuit Power Monitor Meter in IDC Head Cabinet for Pue

Networking

Branch Circuit Power Monitor Meter in IDC Head Cabinet for Pue
Branch Circuit Power Monitor Meter in IDC Head Cabinet for Pue

Installation Instructions

Branch Circuit Power Monitor Meter in IDC Head Cabinet for Pue

Certifications

Branch Circuit Power Monitor Meter in IDC Head Cabinet for Pue
Branch Circuit Power Monitor Meter in IDC Head Cabinet for Pue
 
EMC LVD
 

 

 

 

Company Profile

Branch Circuit Power Monitor Meter in IDC Head Cabinet for Pue

Acrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.
 

Branch Circuit Power Monitor Meter in IDC Head Cabinet for PueBranch Circuit Power Monitor Meter in IDC Head Cabinet for Pue
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier