DTSD1352-4S Multi-Circuit Energy Meter For Tower Base Stations
DTSD1352-4S series DIN-rail type multi-circuit power meter is mainly used for the full electric parametermeasurement of multiple circuits, and can be connected to the current input of 4 three-phase circuits or 12single-phase circuits at the same time. It can measure parameters such as voltage and current, power, power factor,phase angle, unbalance, and harmonics.
Auxiliary Power | AC/DC 85~265V; power consumption≤10VA; | ||
Input Signal | Frequency | 45~65Hz; | |
Voltage | Rated value: AC 3×220V/380V; | ||
Overload: 1.2 times rated value (continuous); 2 times rated value/1 second; | |||
power consumption: ≤ 0.5VA(each channel); | |||
Current | Rated value: Secondary input rated current:50mA | ||
Overload: 1.2 times rated value (continuous); 10 times rated value/1 second; | |||
power consumption: ≤ 0.5VA(each channel); | |||
Measurement Accuracy | Frequency: 0.05Hz, voltage and current: 0.5 class, active energy: 1 class, reactive energy: 2 class; 2nd to 31st harmonic accuracy: ±1%; | ||
Function | Pulse output | Output method: optocoupler pulse with open collector,the pulse constant defaults to 400imp/kWh (and active open input can only be either-or.); | |
communication | RS485 interface, Modbus-RTU protocol; baud rate 1200~38400; | ||
Switch | Input | 2-way or 4-way passive dry contact input, built-in power supply; 2-way active wet node input (AC220V), identify the oil generator and mains access (and pulse output can only be either-or.); |
|
Output | Output method: relay normally open contact output; Contact rating: AC 250V/3A DC 30V/3A; |
||
Safety | Power frequency withstand voltage | >AC 2kV/1min; | |
Insulation resistance | Input and output terminals to the chassis >100MΩ; | ||
Environment | Operating temperature:-20ºC~+60ºC; Storage temperature:-40ºC~+70ºC; Relative humidity:≤95% no condensation; Altitude:≤2500m; |
||
Electromagnetic Compatibility | better than 3 class; |
3-Phase 3-Wire Power Wiring
Shape Dimension(mm) | Rail Dimension(mm) | Tolerance(mm) | ||||
Length | Width | Height | With Terminal Length | |||
Single Module | 87.8 | 72 | 71.5 | 97.7 | 35 | ±1 |
Expanded Communication Module --- AWT100
4G (Global general module)
WiFi
LoRaWAN
LoRa
NB-IoT