Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 80.3/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Acrel DTSD1352 three phase kwh electric meter is designed for three phase energy measurement on low voltage system.The meter meet the related technical requirements of electronic meter in the IEC62053-21.IEC62053-22 standards.Can Match with SunGrow Inverter.
DTSD1352 Three-phase Multi-function DIN Rail Energy Meter
Measurement: U,I,P,Q,S,PF,KWH,KVARH
Voltage Rating: 3×220/380V, 3x380V,3×57.7/100V , 3x100V
Current Rating: 3×10(80)A; 3×1(6)A
Frequency: 45~65Hz
Communication: RS485 (MODBUS-RTU) and Infrared
Display: LCD (8 digits)
Dimension: 127*88*70mm (L*W*H)
Wiring: 3-phase 4wire; 3-phase 3-wire
Installation: 35mm DIN Rail
Standard&Certificate: IEC; CE; EAC
Specification | 3 phase 3 wires, 3 phase 4 wires | |
Voltage |
Reference voltage |
3×100V, 3×380V,3×57.7/100V, 3×220/380V |
Consumption |
<10VA(Single phase) | |
Impedance |
>2MΩ | |
Accuracy class |
Error±0.2% | |
Current |
Input current |
3×1(6)A,3×1(6)A(Outlay transformer),3×10(80)A,3×10(100)A(Outlay transformer) |
Consumption |
<1VA(Single phase rated current) | |
Accuracy class |
Error±0.2% | |
Power |
Active, reactive, apparent power, error±0.5℅ | |
Frequency | 45~65Hz, Error±0.2% | |
Temperature | -40ºC~99ºC | |
Energy |
Active energy(Accuracy class:0.5, 1), reactive energy(Accuracy class 2) | |
Clock |
≤0.5s/d | |
Energy pulse output | 1 active optocoupler output, 1 reactive optocoupler output | |
Switching output | 1 Switching output, Maximum allowed voltage: DC/AC 220V | |
Switching input | 1 optocoupler input,Maximum allowed voltage: DC/AC 220V | |
Width of pulse |
80±20ms | |
Pulse constant |
6400imp/kWh,400imp/kWh(Correspond with the basic current) | |
Interface and communication |
RS485:Modbus RTU | |
Range of communication address |
Modbus RTU:1~ 247; | |
Baud rate |
1200bps~19200bps | |
Relative temperature |
-25ºC~+55ºC | |
Relative humidity |
≤95℅(No condensation) |
Function | Description |
Measurement of energy | All electrical parameters of x-channel three-phase andy-channel single-phase circuits are measured |
Electrical parameters | U,1,F,P,Q,S,PF |
Harmonic | 2-31st voltage and current harmonic |
Extreme value record | U, I, P |
Alarm output | Overvoltage, Over current, Phase break, DI linkage |
Rate setting | 4 rate time zone 14 |
Pulse output | Output mode: optocoupler pulse with open-collector(one out of two with active input) |
communication | RS485 interface, Modbus-RTU, Baud rate 1200~38400 |
DI | 4-channels passive dry contact input, built-in power supply2-channels active wet node input, identify engine oil and power connection(or pulse output) |
DO | Output mode: relay normally open contact output Contact rating: AC 250V/3A DC 30V/3A; |