Acrel Current Input Analog Output Signal Isolator

Product Details
Customization: Available
Type: Electromagnetic
Output Signal Type: Analog Output
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Arabic
Experienced Team
The supplier has 42 foreign trading staff(s) and 33 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (18)
  • Acrel Current Input Analog Output Signal Isolator
  • Acrel Current Input Analog Output Signal Isolator
  • Acrel Current Input Analog Output Signal Isolator
  • Acrel Current Input Analog Output Signal Isolator
  • Acrel Current Input Analog Output Signal Isolator
  • Acrel Current Input Analog Output Signal Isolator
Find Similar Products
  • Overview
  • Product Description
  • Front Panel
  • Features
  • Product Parameters
  • Structure
  • Application
  • Company Profile
Overview

Basic Info.

Model NO.
BM100
Production Process
Integration
Material
Metal
Accuracy Grade
0.2G
IP Rating
IP20
Certification
CE
Customized
Customized
Input Signal
DC0~20mA / 4~20mA
Output Signal
DC0~20mA / 4~20mA
Channel Type
1 in 1 out, 1 in 2 out, 2 in 2 out
Power Supply
DC20~35V
Installation
35mm DIN Rail Installation
Transport Package
Carton
Specification
BM100
Trademark
Acrel
Origin
China
Production Capacity
200000

Packaging & Delivery

Package Size
17.00cm * 15.00cm * 13.00cm
Package Gross Weight
0.500kg

Product Description

 
Acrel BM100 Current Input Analog Output Signal Isolator
Product Description
Acrel Current Input Analog Output Signal Isolator

Input type:Current/Voltage/Thermal resistance Pt100/Resistance/Thermocouple

Input signal: DC 0~20mA /4~20mA,DC 0~5V /1~5V /0~10V,PT100 /0~10K/K, E ,T, J, N, R, S, B

Output signal:0~20mA /4~20mA (Safe side input); Load resistance: ≤550Ω,0~5V /1~5V (Safe side input); Load resistance: ≥330K,0~10V (Safe side input); Load resistance: ≥500K

Power supply: 20~35V DC or 85~265V AC/DC

Application: electric power, railway, petrochemical, metallurgy, chemical industry,food, warehousing and other industries.

BM100 series signal isolators can measure the electrical parameters such as current and voltage ornon-electrical parameters such as temperature and resistance at high speed and accurately, and can be converted into standard analog signal output after the isolation device. It can be directly connected with pointer meter and digital display meter, and can also be connected with automatic control instrument (such as PLC), various A/D converters and computer systems. It is widely used in electric power, railway, petrochemical, metallurgy, chemical industry, food, warehousing and other industries. 

The transmitter outputs one signal, but multiple devices need to access the signal. How to achieve signal distribution?

Installing a signal isolator can quickly and reliably solve the problem of inconsistent signals between devices. On the basis of electrical isolation between input and output signals, the signal isolator can realize the conversion of input signals into output signals according to the 1:1 rule, ensuring the stability and reliability of signal transmission and conversion. The signal isolator is plug-and-play and does not require on-site debugging. It can be quickly installed and used to ensure that the project is delivered on schedule.

--Choose BM100-DII-C12 or BM100-DIIC-C14



Acrel Current Input Analog Output Signal Isolator

Acrel Current Input Analog Output Signal Isolator
Acrel Current Input Analog Output Signal Isolator
Acrel Current Input Analog Output Signal Isolator

 

Front Panel

Acrel Current Input Analog Output Signal Isolator

Features
Acrel Current Input Analog Output Signal Isolator

 

Product Parameters
Channel type Single-way input and single-way output,
single-way input and double-way output,
double-way input and double-way output
Input type Current/Voltage/Thermal resistance Pt100/Resistance
Input signal DC 0~20mA /4~20mA
DC 0~5V /1~5V /0~10V
Pt100(Minimum range: 50ºC)
0~10KΩ(Minimum range: 1KΩ)
Output signal DC 0~20mA /4~20mA ; Load resistance: ≤550Ω
DC 0~5V /1~5V; Load resistance: ≥330KΩ
Load resistance: ≥30KΩ(Pt100/Resistance input)
DC 0~10V /2~10V; Load resistance: ≥500KΩ
Load resistance: ≥30KΩ(Pt100/Resistance input)
Transmission accuracy 0.2%
Temperature modulus 50ppm/ºC (Voltage output: 100ppm/ºC)
Response time 5ms to reach 90% of final value
(RTD Pt100/resistance input: 1s to reach 90% of final value)
Power supply 20~35V DC or 85~265V AC/DC
Work temperature -20ºC~+60ºC
Fix mode Rail installation
Dielectric strength ≥1500V AC/1 min (Among input//output//power supply)
 
Structure

Acrel Current Input Analog Output Signal Isolator

Installation and Wiring 
Acrel Current Input Analog Output Signal IsolatorAcrel Current Input Analog Output Signal IsolatorAcrel Current Input Analog Output Signal IsolatorAcrel Current Input Analog Output Signal IsolatorAcrel Current Input Analog Output Signal IsolatorAcrel Current Input Analog Output Signal Isolator
6 Precautions
6.1 This product must be installed in a safe area, and the surrounding air does not contain any medium that is
corrosive to chromium, nickel and silver plating.
6.2 The input signal type of the two-in-two-out instrument can only select voltage or current signal at the same time.
6.3 Switching between current output and voltage output is not possible, it needs to be done by changing the
hardware, please specify clearly when ordering.
7 Application examples
E.g.1 Input: single-way 4-20mA , output: double-way 4-20mA , power supply: 24V DC
Type: BM100-DI/I-C12
E.g.2 Input: single-way 0-5V, output: double-way 0-20mA , power supply: 220V AC
Type: BM100-DV/I-C12 (Remarks: 220V)
E.g.3 Input: double-way PT100, output: double-way 0-20mA , power supply: 24V DC
Type: BM100-TR/I-C22
E.g.4 Input: single-way4-20mA, output: single-way 4-20mA , power supply: none
Type: BM100-DIS/I-B11
E.g.5 Input: double-way 4-20mA, output: double-way 4-20mA , loop power supply.
Type: BM100-DI/IS-B22
 
Application

Acrel Current Input Analog Output Signal Isolator

Acrel Current Input Analog Output Signal Isolator

Company Profile

Acrel Current Input Analog Output Signal Isolator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now