DTSD1352 is a smart meter designed for power supply system, industrial and mining enterprises and utilities to calculate the electricity consumption and manage the electric demand. It features the high precision, small size and simple installation. It integrates the measurement of all electrical parameters with the comprehensive electricity metering and management provides various data on previous 12 months, checks the 31st harmonic content and the total harmonic content, realizes the remote communication and the remote control with switching input and relay output and boasts the alarm output. It is fitted with RS485 communication port and adapted to MODBUS-RTU. DTSD1352 can be used in all kinds of control systems, SCADA systems and energy management systems. All meters meet the related technical requirements of electronic power meter in the IEC62053-21,IEC62053-22 standards.
Specification | 3 phase 3 wires, 3 phase 4 wires | |
Voltage |
Reference voltage |
3×100V, 3×380V,3×57.7/100V, 3×220/380V |
Consumption |
<10VA(Single phase) | |
Impedance |
>2MΩ | |
Accuracy class |
Error±0.2% | |
Current |
Input current |
3×1(6)A,3×1(6)A(Outlay transformer),3×10(80)A,3×10(100)A(Outlay transformer) |
Consumption |
<1VA(Single phase rated current) | |
Accuracy class |
Error±0.2% | |
Power |
Active, reactive, apparent power, error±0.5℅ | |
Frequency | 45~65Hz, Error±0.2% | |
Temperature | -40ºC~99ºC | |
Energy |
Active energy(Accuracy class:0.5, 1), reactive energy(Accuracy class 2) | |
Clock |
≤0.5s/d | |
Energy pulse output | 1 active optocoupler output, 1 reactive optocoupler output | |
Switching output | 1 Switching output, Maximum allowed voltage: DC/AC 220V | |
Switching input | 1 optocoupler input,Maximum allowed voltage: DC/AC 220V | |
Width of pulse |
80±20ms | |
Pulse constant |
6400imp/kWh,400imp/kWh(Correspond with the basic current) | |
Interface and communication |
RS485:Modbus RTU | |
Range of communication address |
Modbus RTU:1~ 247; | |
Baud rate |
1200bps~19200bps | |
Relative temperature |
-25ºC~+55ºC | |
Relative humidity |
≤95℅(No condensation) |
FAQ
Q: I bought a three-phase four-wire meter, can it be wired as a three-phase three-wire?
A: Yes, press the key to set the meter to three-phase three-wire mode.
Q: What is the difference between ordinary secondary access and -CT (model external transformer)?
A: Ordinary secondary meter could access the ratio XXX/5(1)A of the CTs which could be actual current on-site, the -CT model comes with an external transformer will be convenient for installation(It cannot be disassembled, otherwise it will burn the meter). There are CTs available on site to facilitate with No stitch removal.
Q: What are 3*100V,3*57.7/100V,3*380V,3*220/380V?
A:3*100V, 3*57.7/100V are used for high voltage, used in conjunction with voltage transformers, where 3*100V represents 3P3W,3*57.7V/100V represents 3P4W; 3*380V, 3*220V/380V are used for low voltage, direct voltage input, among them3*380V represents 3P3W, 3*220V/380V represents 3P4W.
Q: Can this meter communicate with PLC?