Customization: | Available |
---|---|
Type: | Hall Type |
Output Signal Type: | Analog Output |
Still deciding? Get samples of US$ 40/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Main featuresLinear error<0.1%
Accuracy error<0.3%
+9V~+16V powered
High-speed CAN2.0B Interface/RS485 interface
working temperature-40ºC- 105ºC
The AHBC-CANB power sensor is a high-precision DC current sensor, which is mainly installed on the busbar of the battery pack to monitor the charging and discharging current. AHBC-CANB adopts fluxgate technology, which has the advantages of high precision.
The fluxgate principle has an absolute technical advantage in the field of high-precision measurement. The continuous oscillation of the excitation magnetic field is equivalent to the degaussing magnetic field, thereby minimizing the hysteresis. Item 4.2.4 of the national standard QCT 897-2011 stipulates that the SOC estimation accuracy requirement is not greater than 10%. In order to ensure this accuracy, the charging and discharging monitoring accuracy should be better than 1%. In order to ensure high-precision SOC under both large current and low current conditions, the full-scale accuracy of the sensor should be further improved by 0.3%. AHBC-CANB power sensor meets the accuracy requirements, and has smaller hysteresis and smaller zero offset.
1.Limit Parameters
Parameters | Symbol | Specs | Condition |
Overvoltage | Uc | 35Vdc | 400ms |
Overvoltage | Uc | 32Vdc | 1min |
Min Operating Voltage | Uc | 18Vdc | Can operate but can't measure |
Max Operating Voltage | Uc | 28Vdc | Can operate but can't measure |
Clearance | DCI | 7mm | / |
Creepage Distance | DCP | 7.2mm | / |
Insulation Resistance | RIS | 500MΩ | 500V, 1min |
IP Rating | / | IP56 | / |
AC Insulation Test Voltage | / | 5kV | 500Hz, 1min |
DC Insulation Test Voltage | / | 5kV | 1min |