Data Center Circuit Monitor

After-sales Service: Yes
Warranty: 1 Years
Display: Digital
Installation: Direct Connected
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter
Electric Equipment: Three-phase Three-wire
Samples:
US$ 193.8/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Function
  • Dimension
  • Installation Instructions
  • Certifications
  • After Sales Service
  • Company Profile
Overview

Basic Info.

Model NO.
AMC16Z-D
Theory
Static Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Power Meter
Certification
CE
Customized
Customized
Communication
RS485, Modbus-RTU
Install
Dinrail
Transport Package
Carton
Specification
AMC16Z-D
Trademark
Acrel
Origin
China
HS Code
9028301400
Production Capacity
200000

Product Description

Product Description

With the rapid development of data centers, the energy consumption of data centers has become more and more prominent, and the energy management and power supply and distribution design of data centers have become hot issues.
An efficient and reliable data center power distribution system solution is an effective way to improve the Power Usage Effectiveness (PUE) of the data center and reduce the energy consumption of equipment.
The AMC series precision power distribution monitoring solution is a complete solution designed for the power distribution monitoring requirements of the column head cabinet in the Internet Data Center (IDC).

Product Parameters

 

Specification AMC16Z-D
Distribution System AC
Measure Bus voltage, current, active power, reactive power, power factor, active energy, reactive energy;
Incoming voltage, current, 2-15th harmonic and total harmonic content;
Outgoing line current 2-15th harmonic and total Harmonic content, current and power maximum demand, neutral voltage, neutral current, temperature, leakage current
Bus Voltage Rated Input 220V AC
Measure Range 40~400V AC
Overload Instantaneous voltage 2 times/30 sec
Current Loop Incoming Line CT Secondary 5A
Range 0~5A
Outgoing Line CT Primary 60A
Range 0.5~60A
Overload Continuous current 1.2 times, Instantaneous current 10 times/ 5 sec
Frequency 45~60Hz
Auxiliary Power AC85~265V / DC100V~350V
Measure Accuracy the Voltage and Current of Incoming Line 0.5
the Power of Incoming Line 1
the Voltage and Current of Outgoing Line 1
the Power of Outgoing Line 2
Consumption 5VA
Insulation resistance 100MΩ
Power frequency withstand voltage Power/Input Signal between ports AC 2KV/1min 50Hz
Environment Temperature Working:-15ºC~+55ºC  Storage:-25ºC~+70ºC
Humidity Relative humidity ≤ 93%
Altitude ≤2500m
Output 2 channels of Switch Value 5A 250VAC/5A 30VDC
Input Switch Value 4-way passive dry contact
Zero sequence current Secondary 0.5~5A
Leakage Current 10mA~1A
Neutral ground voltage 0.2V~20V
Temperature -10ºC~120ºC
Communication 2 channels of Modbus-RTU
Installation DIN35mm  Din-rail
Protection level IP20
Pollution level 2
Electromagnetic Compatibility Anti-static interference 3 grade
Immunity to fast transient bursts 3 grade
Anti-surge interference 4 grade
Resistant to radiofrequency electromagnetic field radiation 3 grade

Function

 

Data Center Circuit Monitor
AMC16Z-D

Outgoing circuit built-in transformer, guide rail installation
1-way incoming line + 21-way outgoing line full power + 21-way active switch
4-channel passive DI+2DO
1 channel temperature + 1 channel zero-sequence current + 1 channel leakage current
1-way zero-ground voltage detection

 

Dimension

Data Center Circuit Monitor

 

Installation Instructions

Data Center Circuit Monitor

Data Center Circuit Monitor
Common faults and cause analysis
1 Inaccurate measurement of the device
      * Check whether the wiring of voltage and current is correct and whether the incoming and outgoing lines of current input are correct;
      * Check whether the CT setting of the device corresponds to the CT actually used externally;
2 Correct voltage and current measurement but inaccurate power measurement
      * Check whether the current input direction is correct;
      * Check whether the corresponding phase of each current loop is correct;
3 Communication is abnormal
      *Check whether the communication cable is connected normally;
      * Check whether the A and B terminals of the communication are interleaved;
      * Check whether the address of the device is set correctly and whether the communication baud rate is set correctly;
      *When the multi-device communication is not normal, first try to see if the single-device communication is normal;
4 Incoming line voltage, current, and power are available, but electric energy has no value
      *Check the CT ratio setting of the incoming line

Certifications

Data Center Circuit Monitor
Data Center Circuit Monitor
 
EMC LVD
 

 

After Sales Service

Data Center Circuit Monitor

 

Company Profile

Data Center Circuit Monitor

Acrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.
 

Data Center Circuit MonitorData Center Circuit Monitor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
Registered Capital
10000000 RMB
Plant Area
>2000 square meters