  • RPP Power Distribution Monitoring for data center applications.
  • Multi circuit power monitoring for centralized distribution management.
  • Monitors up to 192 outgoing distribution circuits.
  • Supports dual A and B power input monitoring.
  • Real time branch circuit power and energy monitoring.
  • Precision power monitoring for critical electrical distribution.
  • Independent alarm thresholds for individual monitoring channels.
  • Supports breaker status and distribution alarm monitoring.
  • RS485 Modbus RTU for power management system integration.
  • AC and DC monitoring solutions for data centers.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure

Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure pictures & photos
Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure pictures & photos
Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure pictures & photos
Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure pictures & photos
Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure pictures & photos
Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure pictures & photos
Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
  • Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
  • Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
    Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
  • Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
    Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
  • Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
    Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
  • Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
    Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
  • Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
    Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
  • Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
    Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure

Find Similar Products

Product Description

RPP Power Distribution Monitoring solution for Data Center
Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure

 
  · RPP Power Distribution Monitoring
Centralized electrical monitoring for remote power panels in data centers.

· Data Center Power Distribution Monitoring
Precision monitoring of critical power distribution infrastructure.

· RPP Branch Circuit Monitoring
Individual branch circuit measurement for detailed load visibility.

· Multi Circuit Power Distribution Monitoring
Centralized monitoring of up to 192 outgoing circuits.

· Dual Feed RPP Power Monitoring
Independent monitoring of A and B power distribution inputs.

· Intelligent RPP Energy Monitoring
Accurate measurement of voltage, current, power and energy consumption.

· Real Time Power Distribution Monitoring
Continuous monitoring of electrical parameters and circuit operating conditions.

· RPP Power Quality Monitoring
Harmonic and electrical unbalance analysis for AC power distribution.

· RPP Alarm and Circuit Status Monitoring
Configurable alarm thresholds and breaker status monitoring.

· Integrated Power Distribution Management
RS485 Modbus RTU communication for centralized monitoring systems.
Wiring


Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure







Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure

 

 
Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure




 
Application

Main Circuit Monitoring
· Voltage, current, power and energy

Branch Circuit Monitoring
· Multi-circuit load and energy measurement

AMC Monitoring Device
· Centralized electrical data collection

RS485 Communication
· Modbus RTU data transmission

Gateway or Touchscreen
· Local display and protocol conversion

Monitoring Platform
· Remote monitoring, alarms and analysis

Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure

 

Project
 
Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure
 
The project is located in Datong city, Shanxi Province

Party A: ByteDance

It covers an area of 537.1 mu

10 data center buildings, 2 complex buildings, 1110 kV substation, 1220kV substation

It can accommodate 600,000 high-performance servers

Construction of the D1~D4 data center building has been started

 
 
Parameters

Product Model

 
Model Function Description
AMC100-ZA Monitoring the full power parameters of the A+B dual three-phase AC incoming circuit, 8 switching status inputs, 4 switching status outputs, 2 leakage monitoring, 1 temperature and humidity detection, 3 RS485 communications
AMC100-FAK30 Monitor the full power parameters and switch status of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication
AMC100-FAK48 Monitor the full power parameters and switch status of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication
AMC100-FA30 Monitor the full power parameters of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication
AMC100-FA48 Monitor the full power parameters of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication
AMC100-KA30 Wet contact, monitor the  switching status of  30 branches A+B, 1 RS485 communication
AMC100-KA48 Wet contact, monitor the  switching status of  48 branches A+B, 1 RS485 communication
AMC100-KD30 Dry contact, monitor the  switching status of  30 branches A+B, 1 RS485 communication
AMC100-KD48 Dry contact, monitor the  switching status of  48 branches A+B, 1 RS485 communication
AMC100-FT30 1 way RS485 communication, 30 way temperature measurement
AMC100-FT48 1 way RS485 communication, 48 way temperature measurement
Model Functional   Description
AMC100-ZD Monitors the voltage, current, power, and electric energy of  2 independent incoming lines A+B,8 switching input, 4 switching output , 1 temperature and humidity detection, and 3  RS485 communications
AMC100-FDK30 Monitor the full power parameters and switching status (active) of A+B dual DC outlet 30 branches ,and 1 RS485 communication
AMC100-FDK48 Monitor the full power parameters and switching status (active) of A+B dual DC outlet 48 branches, and 1 RS485 communication
AMC100-FD30 Monitor the full power parameters of A+B dual DC outgoing lines in A total of 30 branches, and 1 RS485 communication
AMC100-FD48 Monitor the full power parameters of A+B dual DC outgoing lines in A total of 48 branches, and 1 RS485 communication
AMC100-KA30 Wet contact, Monitor the switching status of 30 branches A+B, and 1 RS485 communication
AMC100-KA48 Wet contact, Monitor the switching status of 48 branches A+B, and 1 RS485 communication
AMC100-KD30 Dry contact: Monitor the switching status of 30 branches A+B, and 1 RS485 communication
AMC100-KD48 Dry contact: Monitor the switching status of 48 branches A+B, and 1 RS485 communication
AMC100-FT30 1 channel RS485 communication  and 30 channels temperature measurement
AMC100-FT48 1 channel RS485 communication  and 48 channels temperature measurement

Rpp Power Distribution Monitoring for Rack-Level Power Infrastructure

AC into line

Instrument model AMC100-ZA
Measurement parameters Voltage, current, frequency, active power, reactive power, power factor, active energy, reactive energy, Zero-to-ground voltage, leakage current and zero sequence current, total harmonic content (THD), 2-63 harmonics, current and voltage unbalance, ambient temperature and humidity
Bus voltage Rated 220VAC
 Measuring range ±20%
Overload Instantaneous voltage 2 times/sec
Current incoming circuit Rated Secondary 5A
Range 0~6A
Overload  Continuous 1.2 times, instantaneous 10 times/sec
Temperature and humidity Temperature Range -40ºC~+99ºC
Humidity Range 20%~90%
Input frequency AC45~65Hz

Measurement accuracy
 
Incoming line Voltage/current level 0.2, active power/energy level 0.5, reactive power/energy level 1
Temperature ±1ºC
Humidity ±5%
 Auxiliary power AMC100-ZA: signal to take power (≤15W)
AMC100-ZA-P220: 220V independent power supply
AMC100-ZA-P24: DC 12-24V independent power supply

Environment
 
Temperature Work: -20ºC~150ºC Storage: -25ºC~70ºC
 Humidity Relative humidity≤93%
elevation ≤2500m
Switch output 4 channels 3A 250VAC/3A 30VDC
Switch input 8 dry nodes
Communication 1 isolated RS485/Modbus-RTU to the background system
1 RS485/Modbus-RTU to touch screen
 1 RS485/Modbus-RTU connection downstream module
 Optional 1-channel Ethernet communication function
Installation Method DIN35mm rail or bottom plate installation
Protection level IP20
 Pollution level 2


Security
 
Insulation The insulation resistance between all terminals and the conductive parts of the shell is not less than 100MΩ
Withstand voltage A voltage and current signal//B voltage and current signal//switch output//isolated communication port//between other ports meet AC2kV 1min, switch input and other ports should meet AC0.5kV 1min, leakage current Should be less than 2mA, no breakdown or flashover phenomenon.



AC outlet

Instrument model AMC100-FAK30 AMC100-FAK48
 Measurement parameters Voltage, current, frequency, active power, reactive power, power factor, active energy, reactive energy, 2-31 times total current harmonic content

Bus voltage
Rated 220VAC
Measuring range ±20%
 Overload Instantaneous voltage 2 times/sec
Current outlet loop Rated 50mA
Range 0.125~60mA
 Overload Continuous 1.2 times, instantaneous 10 times/sec
Input frequency AC45~65Hz
Measure Outlet Voltage/current/active power/active energy level 0.5, reactive power/reactive energy level 1
Auxiliary power Powered by AMC100-ZA; DC 12-24V power supply when used alone
Environment  Temperature Work: -15ºC~55ºC Storage: -25ºC~70ºC
Humidity Relative humidity≤93%
 elevation ≤2500m
 Communication RS485/Modbus-RTU
Installation Method DIN35mm rail or bottom plate installation
Protection level IP20
 Pollution level 2


Security
 
Insulation The insulation resistance between all terminals and the conductive parts of the shell is not less than 100MΩ
Withstand voltage The voltage and current signals of circuit A//the voltage and current signals of circuit B//other ports meet AC2kV for 1min, the leakage current should be less than 2mA, and there is no breakdown or flashover.
 


DC into line

Instrument model AMC100-ZD
Measured parameters Voltage, Current, Power, Electric energy, Ambient temperature and Humidity
Bus voltage Rated 48VDC,240VDC,336VDC
Measuring range ±20%
Overload Instantaneous voltage 2 times per second
Current incoming circuit Rated 5V(Hall sensor, ±12V powered by AMC100-ZD)
Overload Duration is 1.2 times, instantaneous 10 times/second
Temperature and humidity Temperature range -40ºC~+99ºC
Humidity range 20%~90%
Measuring accuracy Coil in Voltage/current level 0.5, power/electric energy level 1
Temperature ±1ºC
Humidity ±5%
Auxiliary  supply
AMC100-ZD:Signal power(≤15W)
AMC100-ZD-P24:DC 12-24V independent power supply
AMC100-ZD-P220:
1.When the constant voltage is DC 240V,DC336V,powered by AC220V,DC240V ,DC336V independent supply
2.When the constant voltage is DC 48V,powered by DC48V independent supply
Environment Temperature Operation:-15ºC~55ºC  Storage:-25ºC~70ºC
Humidity Relative humidity≤93%
Altitude ≤2500m
Switching output 4-way 3A 250VAC /3A 30VDC
Switch input 8 dry nodes
Communication 1 channel isolated RS485/Modbus-RTU to the background system
1 RS485/Modbus-RTU to touch screen
1 RS485/Modbus-RTU connection to the downstream module
1-channel Ethernet communication function is optional
Installation Method DIN35mm rail or bottom plate installation
Protection level IP20
Pollution level 2
Security Insulation The insulation resistance between all terminals and the conductive parts on the shell must be at least 100MΩ
Withstand voltage Voltage and current signal of line A // Voltage and current signal of line B // Switching output // Isolated communication port // Two of other ports should meet AC2kV for 1min, switching input and other ports should meet AC0.5kV for 1min, leakage current should be less than 2mA, no breakdown or flashover phenomenon.



DC  outlet

Instrument model AMC100-FDK30 AMC100-FDK48
Measuring parameters Voltage, Current, Power, Electric energy
Bus voltage Rated 48VDC,240VDC,336VDC
Measuring range ±20%
Overload Instantaneous voltage 2 times per second  
Current incoming circuit Rated 5V (Hall sensor, need external power supply ±12V or ±15V)
Range
Overload Duration is 1.2 times, instantaneous 10 times/second
Measuring accuracy coil out Voltage/current level 0.5, power/electric energy level 1
Auxiliary  supply Powered by AMC100-ZD; DC 12-24V power supply when used alone
Environment Temperature Operation:-15ºC~55ºC  Storage:-25ºC~70ºC
Humidity Relative humidity≤93%
Altitude ≤2500m
Communication RS485/Modbus-RTU
Installation Method DIN35mm rail or bottom plate installation
Protection level IP20
Pollution level 2
Security Insulation The insulation resistance between all terminals and the conductive parts on the shell must be at least 100MΩ
Withstand voltage Voltage and current signal of line A // Voltage and current signal of line B // The two of other ports meet AC2kV for 1min, the leakage current should be less than 2mA, and no breakdown or flashover phenomenon.  




 

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR2541377". Items marked "verified" are certified.

Watch Video
Watch Video
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Jiangsu Acrel Electrical Manufacturing Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
No. 5, Dongmeng Road, Dongmeng Industrial Park, Nanzha Street, Jiangyin City, Wuxi, Jiangsu, China
verified Number of Employees
307
verified Registered Capital
326,860,200 RMB
verified Terms of Payment
LC, T/T, PayPal, D/P, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shanghai Port
verified Minimum Order Quantity
1 PC
verified Supply Chain Partners
164

Our Production Capability & Technical Expertise

Main Products
Power Meter, Energy Meter, WiFi Meter, RS485 Modbus-RTU Meter, Multifunction Relay, Motor Protection Relay, Busbar Temperature Sensor, Power Tag, Insulation Monitor, Current Sensor
verified Production Lines
3
verified Production Machines
SMT Line, Assembling Line, Auto Processing Line
verified QA/QC inspectors
24 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
32 people
verified Traceability of Raw Materials
Yes
verified Test Reports for Raw Materials
UL, Others

Our Industry Experience & Global Business Record

verified Year of Establishment
2004-12-14
verified Export Year
8 Years
verified Main Markets
North America, Europe, Southeast Asia/ Mideast
verified Repeat Buyers Choice
80%~100%
verified Number of Foreign Trading Staff
18
verified Overseas Agent/Branch
Yes
verified New Products Launched in Last year
Yes

FAQ

What is an RPP Power Distribution Monitoring System?
An RPP Power Distribution Monitoring System monitors electrical parameters, energy consumption and circuit status in remote power panels used in data centers.
How many circuits can this RPP monitoring system monitor?
The AMC100 system supports dual A and B power inputs and can monitor up to 192 outgoing circuits with the appropriate module configuration.
Can this system monitor individual branch circuits?
Yes, it supports individual branch circuit monitoring, including current, power and energy measurements, depending on the selected modules.
Is this power distribution monitoring system suitable for data centers?
Yes, it is designed for data center precision power distribution monitoring, including multi circuit measurement, power management and alarm monitoring.
Does the RPP monitoring system support both AC and DC power distribution?
Yes, the AMC100 series offers dedicated AC and DC monitoring models. The appropriate version should be selected according to the distribution system.