Acrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric Parameters

Product Details
Customization: Available
Rated Voltage: 230V (1p/2p), 400V (3p/4p)
Rated Current: 16A, 32A, 63A
Still deciding? Get samples of US$ 62/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Arabic
Experienced Team
The supplier has 42 foreign trading staff(s) and 33 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (17)
  • Acrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric Parameters
  • Acrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric Parameters
  • Acrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric Parameters
  • Acrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric Parameters
  • Acrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric Parameters
  • Acrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric Parameters
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
  • Dimension
  • Photos on Site
  • FAQ
  • Company Profile
Overview

Basic Info.

Model NO.
ASCB1-63
Mechanical Life
20000 Times
Electrical Life
6000 Times
Breaking Capacity
6000A
Instantaneous Unbuckle Type
C/D
Transport Package
Carton
Trademark
Acrel
Origin
China
Production Capacity
200000 PCS/Yaer

Packaging & Delivery

Package Size
17.00cm * 15.00cm * 13.00cm
Package Gross Weight
0.500kg

Product Description

Product Description
Acrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric Parameters

 Rated voltage:230V (1P/2P), 400V (3P/4P)

 Rated current:16A,32A,63A

 Rated short-circuit breaking capacity: 6000A

 Real-time monitoring of electric parameters such as voltage, current, power, electrical energy and temperature

 overvoltage, undervoltage, overload, short circuit, overcurrent and overtemperature protection

 With local manual push rod, local electric control, local lock, remote control, timing control and so on

RS485(Modbus-RTU) standard, with Ethernet and 4G optional


ASCB1 series intelligent miniature circuit breakers (hereinafter referred to as intelligent miniature circuit breakers) are used in low-voltage terminal power distribution networks in industrial, commercial, civil buildings and infrastructures in indoor buildings and similar places. The intelligent miniature circuit breaker is used in conjunction with the intelligent gateway to conduct real-time monitoring of the key electrical parameters of the power line, such as voltage, current,power, temperature, leakage, energy consumption, fault location and other functions etc.

This series of products can choose single pole, 2 pole, 3 pole and 4 pole .

Acrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric Parameters
Acrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric Parameters
 

 

Product Parameters
Model
ASCB1-63
ASCB1LE-63
Pole
1P/2P/3P/4P
2P/4P
Grade of Shell
63A
Rated Voltage
230V(1P/2P),400V(3P/4P)
Rated Current
6A,10A,16A,20A,25A,32A,40A,50A,63A
Instantaneous Unbuckle Type
C/D
Rated Short-circuit Breaking Capacity
6000A
 
 
 
 
 
 
 
 
Protect
Over-current Protection
Default 100% rated current alert,
110% Rated current trip with adjustable threshold
Short-circuit Protection
5-10 Rated current for 0.04 seconds for circuit break protection
Overload Protection
Default 100% rated power alert,110% Rated power trip with adjustable threshold
Over-voltage Protection
Default 110% rated voltage alert,120% rated voltage trip with adjustable threshold
Under-voltage Protection
Default 90% rated voltage alert,80% rated voltage trip with adjustable threshold
Over-temperature Protection
Default 80ºC alert,100ºC trip, the threshold is adjustable
Leakage Protection
No
Default 20mA alert, 30mA trip, the threshold is adjustable
Leakage self-Inspection
No
Manual button self-inspection
Mechanical Life
20000 times
Electrical Life
6000 times
Levels of Protection
IP20
Connection Capacity
1-35mm²
Elevation Requirements
2000m
Ambient Temperature
-10ºC~55ºC,the average temperature at 24h was no higher than 40ºC
Environmental Requirements
No explosion hazard, no conductive dust, no sufficient corrosion of metal and damaged insulation, no significant vibration
Relative Humidity
At + 40ºC, the relative humidity of the air is 50% and can have high relative humidity at lower temperatures
Storage Temperature
-20ºC-70ºC
Class of Pollution
II
Installation Type
III
Way to Installation
Standard 35mm guide rail installation
Installation Instructions

 

1) The device is suitable for standard 35mm rail type installation. When installing, just clip the device into the rail and fix it with a buckle .
2) According to the actual power distribution management and line laying design requirements, select and use IoT modules and electrical boxes that meet the needs.
The specifications of the box are assembled and installed in the order of the modules shown in the figure, and each module is connected by a special 8PIN data cable made by the manufacturer.
3) The circuit breaker should be installed vertically. When the handle is in "/OFF", the contacts are disconnected. When the handle moves upward, the contacts move in the closing direction;
4) See Table 5 for the nominal cross-sectional area of the connecting copper wire that matches the rated current of the circuit breaker.

Acrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric Parameters5) During installation, please tighten the copper wire with the torque specified in Table 5. After installation, check whether the copper wire is firmly connected by shaking the wire, and then tighten the copper wire with the specified torque again. Figure 5 is an example of the installation and wiring of the smart miniature circuit breaker, for reference only.
Acrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric Parameters
Acrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric Parameters

Dimension

Acrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric ParametersAcrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric Parameters

Photos on Site

Application 

Acrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric Parameters

Acrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric ParametersAcrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric Parameters
 
FAQ

Q: Can the circuit breaker data be collected through RS485 communication?

 

A: The circuit breaker has its own RS485 communication interface, and it does not need to be equipped with an ASCB1-M gateway to access the customer system, but the customer needs to provide the circuit breaker with DC12V 12A auxiliary power supply

 

 

 

Q: How many circuit breakers can a gateway carry?

 

A: 16PCS

 

Q: How Gateways and Circuit Breakers are Networked?

 

A: The gateway and the circuit breaker are connected by a 4pin cable, a set of DC12V auxiliary power supply, and a set of RS485 communication lines.
The connection between the circuit breaker and the circuit breaker is the same.
One-key addressing operation through the gateway

 

Q: Does the circuit breaker need to be equipped with additional accessories?

 

A: 1. Internally integrate various sensor modules, including: current sensor, leakage transformer, temperature sensor, etc.;
2. The circuit breaker integrates the release function, which can realize remote opening and closing operations;
3. Configure the circuit breaker network cable

Company Profile

Acrel Smart Miniature Circuit Breaker for Real-Time Monitoring of Electric Parameters

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier