Main Circuit Monitoring
· Voltage, current, power and energy
Branch Circuit Monitoring
· Multi-circuit load and energy measurement
AMC Monitoring Device
· Centralized electrical data collection
RS485 Communication
· Modbus RTU data transmission
Gateway or Touchscreen
· Local display and protocol conversion
Monitoring Platform
· Remote monitoring, alarms and analysis
Product Model
| Model | Function Description |
| AMC100-ZA | Monitoring the full power parameters of the A+B dual three-phase AC incoming circuit, 8 switching status inputs, 4 switching status outputs, 2 leakage monitoring, 1 temperature and humidity detection, 3 RS485 communications |
| AMC100-FAK30 | Monitor the full power parameters and switch status of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication |
| AMC100-FAK48 | Monitor the full power parameters and switch status of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication |
| AMC100-FA30 | Monitor the full power parameters of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication |
| AMC100-FA48 | Monitor the full power parameters of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication |
| AMC100-KA30 | Wet contact, monitor the switching status of 30 branches A+B, 1 RS485 communication |
| AMC100-KA48 | Wet contact, monitor the switching status of 48 branches A+B, 1 RS485 communication |
| AMC100-KD30 | Dry contact, monitor the switching status of 30 branches A+B, 1 RS485 communication |
| AMC100-KD48 | Dry contact, monitor the switching status of 48 branches A+B, 1 RS485 communication |
| AMC100-FT30 | 1 way RS485 communication, 30 way temperature measurement |
| AMC100-FT48 | 1 way RS485 communication, 48 way temperature measurement |
| Model | Functional Description |
| AMC100-ZD | Monitors the voltage, current, power, and electric energy of 2 independent incoming lines A+B,8 switching input, 4 switching output , 1 temperature and humidity detection, and 3 RS485 communications |
| AMC100-FDK30 | Monitor the full power parameters and switching status (active) of A+B dual DC outlet 30 branches ,and 1 RS485 communication |
| AMC100-FDK48 | Monitor the full power parameters and switching status (active) of A+B dual DC outlet 48 branches, and 1 RS485 communication |
| AMC100-FD30 | Monitor the full power parameters of A+B dual DC outgoing lines in A total of 30 branches, and 1 RS485 communication |
| AMC100-FD48 | Monitor the full power parameters of A+B dual DC outgoing lines in A total of 48 branches, and 1 RS485 communication |
| AMC100-KA30 | Wet contact, Monitor the switching status of 30 branches A+B, and 1 RS485 communication |
| AMC100-KA48 | Wet contact, Monitor the switching status of 48 branches A+B, and 1 RS485 communication |
| AMC100-KD30 | Dry contact: Monitor the switching status of 30 branches A+B, and 1 RS485 communication |
| AMC100-KD48 | Dry contact: Monitor the switching status of 48 branches A+B, and 1 RS485 communication |
| AMC100-FT30 | 1 channel RS485 communication and 30 channels temperature measurement |
| AMC100-FT48 | 1 channel RS485 communication and 48 channels temperature measurement |
AC into line
| Instrument model | AMC100-ZA | |
| Measurement parameters | Voltage, current, frequency, active power, reactive power, power factor, active energy, reactive energy, Zero-to-ground voltage, leakage current and zero sequence current, total harmonic content (THD), 2-63 harmonics, current and voltage unbalance, ambient temperature and humidity | |
| Bus voltage | Rated | 220VAC |
| Measuring range | ±20% | |
| Overload | Instantaneous voltage 2 times/sec | |
| Current incoming circuit | Rated | Secondary 5A |
| Range | 0~6A | |
| Overload | Continuous 1.2 times, instantaneous 10 times/sec | |
| Temperature and humidity | Temperature Range | -40ºC~+99ºC |
| Humidity Range | 20%~90% | |
| Input frequency | AC45~65Hz | |
Measurement accuracy |
Incoming line | Voltage/current level 0.2, active power/energy level 0.5, reactive power/energy level 1 |
| Temperature | ±1ºC | |
| Humidity | ±5% | |
| Auxiliary power | AMC100-ZA: signal to take power (≤15W) AMC100-ZA-P220: 220V independent power supply AMC100-ZA-P24: DC 12-24V independent power supply |
|
Environment |
Temperature | Work: -20ºC~150ºC Storage: -25ºC~70ºC |
| Humidity | Relative humidity≤93% | |
| elevation | ≤2500m | |
| Switch output | 4 channels 3A 250VAC/3A 30VDC | |
| Switch input | 8 dry nodes | |
| Communication | 1 isolated RS485/Modbus-RTU to the background system 1 RS485/Modbus-RTU to touch screen 1 RS485/Modbus-RTU connection downstream module Optional 1-channel Ethernet communication function |
|
| Installation Method | DIN35mm rail or bottom plate installation | |
| Protection level | IP20 | |
| Pollution level | 2 | |
Security |
Insulation | The insulation resistance between all terminals and the conductive parts of the shell is not less than 100MΩ |
| Withstand voltage | A voltage and current signal//B voltage and current signal//switch output//isolated communication port//between other ports meet AC2kV 1min, switch input and other ports should meet AC0.5kV 1min, leakage current Should be less than 2mA, no breakdown or flashover phenomenon. | |
AC outlet
| Instrument model | AMC100-FAK30 | AMC100-FAK48 | |
| Measurement parameters | Voltage, current, frequency, active power, reactive power, power factor, active energy, reactive energy, 2-31 times total current harmonic content | ||
Bus voltage |
Rated | 220VAC | |
| Measuring range | ±20% | ||
| Overload | Instantaneous voltage 2 times/sec | ||
| Current outlet loop | Rated | 50mA | |
| Range | 0.125~60mA | ||
| Overload | Continuous 1.2 times, instantaneous 10 times/sec | ||
| Input frequency | AC45~65Hz | ||
| Measure | Outlet | Voltage/current/active power/active energy level 0.5, reactive power/reactive energy level 1 | |
| Auxiliary power | Powered by AMC100-ZA; DC 12-24V power supply when used alone | ||
| Environment | Temperature | Work: -15ºC~55ºC Storage: -25ºC~70ºC | |
| Humidity | Relative humidity≤93% | ||
| elevation | ≤2500m | ||
| Communication | RS485/Modbus-RTU | ||
| Installation Method | DIN35mm rail or bottom plate installation | ||
| Protection level | IP20 | ||
| Pollution level | 2 | ||
Security |
Insulation | The insulation resistance between all terminals and the conductive parts of the shell is not less than 100MΩ | |
| Withstand voltage | The voltage and current signals of circuit A//the voltage and current signals of circuit B//other ports meet AC2kV for 1min, the leakage current should be less than 2mA, and there is no breakdown or flashover. | ||
DC into line
| Instrument model | AMC100-ZD | |
| Measured parameters | Voltage, Current, Power, Electric energy, Ambient temperature and Humidity | |
| Bus voltage | Rated | 48VDC,240VDC,336VDC |
| Measuring range | ±20% | |
| Overload | Instantaneous voltage 2 times per second | |
| Current incoming circuit | Rated | 5V(Hall sensor, ±12V powered by AMC100-ZD) |
| Overload | Duration is 1.2 times, instantaneous 10 times/second | |
| Temperature and humidity | Temperature range | -40ºC~+99ºC |
| Humidity range | 20%~90% | |
| Measuring accuracy | Coil in | Voltage/current level 0.5, power/electric energy level 1 |
| Temperature | ±1ºC | |
| Humidity | ±5% | |
| Auxiliary supply |
AMC100-ZD:Signal power(≤15W)
AMC100-ZD-P24:DC 12-24V independent power supply AMC100-ZD-P220:
1.When the constant voltage is DC 240V,DC336V,powered by AC220V,DC240V ,DC336V independent supply
2.When the constant voltage is DC 48V,powered by DC48V independent supply
|
|
| Environment | Temperature | Operation:-15ºC~55ºC Storage:-25ºC~70ºC |
| Humidity | Relative humidity≤93% | |
| Altitude | ≤2500m | |
| Switching output | 4-way 3A 250VAC /3A 30VDC | |
| Switch input | 8 dry nodes | |
| Communication | 1 channel isolated RS485/Modbus-RTU to the background system 1 RS485/Modbus-RTU to touch screen 1 RS485/Modbus-RTU connection to the downstream module 1-channel Ethernet communication function is optional |
|
| Installation | Method DIN35mm rail or bottom plate installation | |
| Protection level | IP20 | |
| Pollution level | 2 | |
| Security | Insulation | The insulation resistance between all terminals and the conductive parts on the shell must be at least 100MΩ |
| Withstand voltage | Voltage and current signal of line A // Voltage and current signal of line B // Switching output // Isolated communication port // Two of other ports should meet AC2kV for 1min, switching input and other ports should meet AC0.5kV for 1min, leakage current should be less than 2mA, no breakdown or flashover phenomenon. | |
DC outlet
| Instrument model | AMC100-FDK30 | AMC100-FDK48 | |
| Measuring parameters | Voltage, Current, Power, Electric energy | ||
| Bus voltage | Rated | 48VDC,240VDC,336VDC | |
| Measuring range | ±20% | ||
| Overload | Instantaneous voltage 2 times per second | ||
| Current incoming circuit | Rated | 5V (Hall sensor, need external power supply ±12V or ±15V) | |
| Range | |||
| Overload | Duration is 1.2 times, instantaneous 10 times/second | ||
| Measuring accuracy | coil out | Voltage/current level 0.5, power/electric energy level 1 | |
| Auxiliary supply | Powered by AMC100-ZD; DC 12-24V power supply when used alone | ||
| Environment | Temperature | Operation:-15ºC~55ºC Storage:-25ºC~70ºC | |
| Humidity | Relative humidity≤93% | ||
| Altitude | ≤2500m | ||
| Communication | RS485/Modbus-RTU | ||
| Installation | Method DIN35mm rail or bottom plate installation | ||
| Protection level | IP20 | ||
| Pollution level | 2 | ||
| Security | Insulation | The insulation resistance between all terminals and the conductive parts on the shell must be at least 100MΩ | |
| Withstand voltage | Voltage and current signal of line A // Voltage and current signal of line B // The two of other ports meet AC2kV for 1min, the leakage current should be less than 2mA, and no breakdown or flashover phenomenon. | ||