Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 240/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type | APM800 | |
Technical Parameters | Index | |
Signal | Electrical network | Three-phase three-wire, three-phase four-wire, see the wiring diagram; |
Frequency | 45~65Hz; | |
Voltage | Rated value: AC 100V,110V,400V,690V; | |
Overload: 1.2 times rated value(continuous); 2 times rated value /1 second; | ||
Power consumption: < 0.5VA (per channel); | ||
Current | Rated value: AC 1A, 5A, support 4 mm2 line access; | |
Overload: 1.2 times rated value(continuous); 10 times rated value/1 second; | ||
Power consumption: < 0.5VA (per channel); | ||
Measurement accuracy | Voltage,current and power | Class 0.5S |
Active power | Class 0.5S | |
Reactive power | Class 2.0 | |
Switch inputs | Dry contact inputs, built-in power supply; | |
Relay outputs | Contact type | open contact in main part, changeover contact in module |
Contact capacity | AC 250V/3A DC 30V/3A | |
Pulse output of energy | Output mode | Optocoupler pulse with open collector |
Pulse constant | 4000(5A),8000(1A) imp/kWh | |
Analog outputs | DC 0mA~20mA,4mA~20mA,0V~5V,1V~5V output, accuracy class 0.5%, load resistance ≤ 500Ω | |
Analog inputs | DC 0mA~20mA,4mA~20mA,0V~5V,1V~5V iutput, accuracy class 0.5% | |
Storage card | Standard Capacity | 4G |
maximum Capacity | TF Card Up to 32G Capacity | |
Communication | RS485 interface/Modbus-RTU protocol and DLT645 protocol | |
Profibus-DP interface/Profibus-DP protocol; | ||
RJ45 interface (Ethernet) / Modbus-TCP, http, DHCP and other protocols; | ||
Power supply | Working range | AC/DC 85V~265V or AC/DC 115~415V(P2) |
Power consumption | Power consumption of the main part ≤ 15VA | |
Safety | Power frequency withstand voltage | The power frequency withstand voltage between the shell and the auxiliary power supply, each input and output terminal group is AC 4kV/1min; |
The power frequency withstand voltage between the auxiliary power supply and each input and each output terminal group is AC 2kV/1min; | ||
The power frequency withstand voltage between the voltage input and other input/output terminal groups is AC 2kV/1min; | ||
The power frequency withstand voltage between the current input and other input/output terminal groups is AC 2kV/1min; | ||
The power frequency withstand voltage between the relay output and other input/output terminal groups is AC 2kV/1min; | ||
The power frequency withstand voltage between each terminal group of switch input, communication, analog output and pulse output is AC 1kV/1min; | ||
Insulation resistance | Inputs,outputs to the shell>100MΩ; | |
Electromagnetic compatibility | Meet IEC 61000 standard (Level 4); | |
Protection level | Display panel | IP52 |
Environment | Operating temperature | -20°C~ +65°C |
Storage temperature | -20°C~ +70°C | |
Relative humidity | ≤95% without condensation | |
Altitude | ≤2500m | |
Standards | IEC 60068-2-1 | Environmental Testing-Part 2-1:Tests Test A:Cold IDA |
IEC 60068-2-2 | Part 2-1:Tests Test B:Dry heat | |
IEC 60068-2-30 | Part 2-30:Tests Test Db:Damp heat,cyclic(12+12h) | |
IEC 61000-4 | Electromagnetic compatibility-Testing and measurement techniques | |
IEC 61557-12 | Electrical safety in low voltage distribution system up to 1000V a.c. and1500V d.c -Equipment for testing,measuring or monitoring of protective measures- Part12:Performances measuring and monitoring devices(PMD) | |
IEC 62053-22 | Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2s and 0.5s) | |
IEC 62053-24 | Electricity metering equipment (a.c.)-Particular requirements - Part24:Static meter for reactive energy at fundamental frequency (classes 0.5S 1S and 1) |
Full Electric Parameters Measurement
3-phase (I, U, kW, kVar, kWh, Hz, cosφ)
Current&Voltage Unbalance
Harmonic (THD & 2~63rd)
Real-time&Max Demand
Extremum of this month&last month
Zero-sequence Current
4-quadrant Energy
Diverse Extra Function Module
Modular Design (Easy for Function Expansion)
Support up to 3 Expanded Module at same time
DO/DI Switch Function Module ---MD82
2 DO Relay Output
8 DI Digital Input
Save up to 128 pcs DO/DI Data in Main Body
Paired with MLOG to save more DO/DI Records
SD Card Data Storage Module ---MLOG
Expand Number of SOE Storage
Support Storage of SD Cards up to 32GB (standard 4GB)
Extra RS485 Communication Module ---MCM
Interface: RS485 Interface
Protocol: MODBUS-RTU
Support Salve&Master Mode
Ethernet Communication Module ---MCME
Interface: RJ45 Interface
Protocol: MODBUS-TCP/HTTP/DHCP/SMTP
Could Serve as Serial Server
Plus 1 Extra RS485 Interface
PROFIBUS-DP Communication Module ---MCMP
Interface: PROFIBUS-DP Interface
Protocol: PROFIBUS-DP
Plus 1 Extra RS485 Interface
SOE Function (Main Body)
Alarm Record (128 pcs records of 66 kinds&13 categories)
DO/DI Record (128 pcs DO/DI records)
Transient Record (800 pcs transient waveform records)
Max Records pcs above could be expanded by SD Card
Multi-rate/Multi-tariff
4 Time zone
4 Tariff rate (Spike, Peak, Flat, Valley)
2 Time period list
14 Time period by day
Local Configuration
Keypads HMI for Programming
Setting through Adjustment Software
Setting through WEB
Setting through MODBUS communication
APM800 Three Phase Multifunction Power Meter is secondary current access and panel mounted installation. The overall size of the meter is L*W*H: 92*92*65mm, the front panel has the LCD screen, including Type of parameters, Load value, Total Power, DI/DO status, Data display, Navbar, Buttons etc. Its installation as follows: Cut out a 92mm*92mm hole on the panel, unleash all the static, move off installation terminal, put in the panel, fixed the meter on the panel by using the incidental brackets with buckle, installation complete.
0.5S High precision, CE certification
Diverse functions, full electric parameter measurement
Modular design, various optioned functions
Can realize wireless communication with gateway module
Electric power monitoring in industrial and mining enterprises
Energy consumption monitoring in petrochemical industry
Electric power monitoring of municipal works
Hotel apartment, education and medical electrical safety monitoring
The meter is equipped with standard 4G SD card while saving the data of electrical parameter, energy, event, SOE, alarm. Also, the setting of storage interval could be changed. (1 min interval for electrical parameter and 1 hour interval for energy)
*How should I select the expanded modules of APM800?
Our users can select 3 of the optional modules at will even repeatedly except for communication module. Also, the order of module installation could be random.
*The features of APM800?
Except for wave record and SD card storage function, 0.2S measuring accuracy can also be a option. Besides, APM8xx can serve as reverse display meter (which means 3-phase electrical parameters measuring plus 8-channel reverse display) Also, users can measure the data through browser by using Ethernet auto WEB.
*As for the auxiliary power supply of APM800?