Customization: | Available |
---|---|
Rated Voltage: | 230V (1p/2p), 400V (3p/4p) |
Rated Current: | 16A, 32A, 63A |
Still deciding? Get samples of US$ 62/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1) Powerful functions: protection, metering, and control are integrated. Only one circuit breaker is needed to replace multiple products, realizing high integration of equipment;
2) Convenient installation: the equipment is small in size, and the installation method is basically the same as that of traditional circuit breakers. It is suitable for various installation environments and has a wide range of application scenarios;
3) Reduce costs: The high integration of equipment greatly saves the cost of manpower construction wiring and the purchase of various equipment;
4) Improve efficiency: The equipment status of the three terminals, device terminal, web terminal, and mobile terminal, is displayed synchronously. Users can monitor the equipment anytime and anywhere. The platform timely updates the month-on-month statistical analysis of energy consumption, which is convenient for users to quickly formulate energy-saving plans.
Model
|
ASCB1-63
|
ASCB1LE-63
|
||
Pole
|
1P/2P/3P/4P
|
2P/4P
|
||
Grade of Shell
|
63A
|
|||
Rated Voltage
|
230V(1P/2P),400V(3P/4P)
|
|||
Rated Current
|
6A,10A,16A,20A,25A,32A,40A,50A,63A
|
|||
Instantaneous Unbuckle Type
|
C/D
|
|||
Rated Short-circuit Breaking Capacity
|
6000A
|
|||
Protect
|
Over-current Protection
|
Default 100% rated current alert,
110% Rated current trip with adjustable threshold
|
||
Short-circuit Protection
|
5-10 Rated current for 0.04 seconds for circuit break protection
|
|||
Overload Protection
|
Default 100% rated power alert,110% Rated power trip with adjustable threshold
|
|||
Over-voltage Protection
|
Default 110% rated voltage alert,120% rated voltage trip with adjustable threshold
|
|||
Under-voltage Protection
|
Default 90% rated voltage alert,80% rated voltage trip with adjustable threshold
|
|||
Over-temperature Protection
|
Default 80ºC alert,100ºC trip, the threshold is adjustable
|
|||
Leakage Protection
|
No
|
Default 20mA alert, 30mA trip, the threshold is adjustable
|
||
Leakage self-Inspection
|
No
|
Manual button self-inspection
|
||
Mechanical Life
|
20000 times
|
|||
Electrical Life
|
6000 times
|
|||
Levels of Protection
|
IP20
|
|||
Connection Capacity
|
1-35mm²
|
|||
Elevation Requirements
|
2000m
|
|||
Ambient Temperature
|
-10ºC~55ºC,the average temperature at 24h was no higher than 40ºC
|
|||
Environmental Requirements
|
No explosion hazard, no conductive dust, no sufficient corrosion of metal and damaged insulation, no significant vibration
|
|||
Relative Humidity
|
At + 40ºC, the relative humidity of the air is 50% and can have high relative humidity at lower temperatures
|
|||
Storage Temperature
|
-20ºC-70ºC
|
|||
Class of Pollution
|
II
|
|||
Installation Type
|
III
|
|||
Way to Installation
|
Standard 35mm guide rail installation
|
Step1: Connect the RS485 port on the gateway to the BUS port of the circuit breaker by using the communication cable provided by the gateway | Step2: Insert the barbed side of the connecting wire of the circuit breaker into the external terminal of the previous circuit breaker toward the outside of the terminal, and the colors need to be matched one by one. |