Acrel DC Leakage Current Sensor Transducer for Current Differential Detection

Product Details
Customization: Available
Type: Electromagnetic
Output Signal Type: Analog Output
Still deciding? Get samples of US$ 9.1/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Arabic
Experienced Team
The supplier has 42 foreign trading staff(s) and 33 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (18)
  • Acrel DC Leakage Current Sensor Transducer for Current Differential Detection
  • Acrel DC Leakage Current Sensor Transducer for Current Differential Detection
  • Acrel DC Leakage Current Sensor Transducer for Current Differential Detection
  • Acrel DC Leakage Current Sensor Transducer for Current Differential Detection
  • Acrel DC Leakage Current Sensor Transducer for Current Differential Detection
  • Acrel DC Leakage Current Sensor Transducer for Current Differential Detection
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Dimension
  • Wiring
  • Installation Instructions
  • After Sales Service
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
AHLC
Production Process
Integration
Material
Metal
Accuracy Grade
1.0G
Application
Ad, DSP, PLC, Energy Meter
IP Rating
IP40
Certification
IEC, RoHS
Customized
Customized
Input
10mA-2A
Output
5V
Auxiliary Power
+15V, -15V
Transport Package
Carton
Specification
AHLC
Trademark
Acrel
Origin
China
HS Code
9030339000
Production Capacity
200000

Packaging & Delivery

Package Size
17.00cm * 15.00cm * 13.00cm
Package Gross Weight
0.500kg

Product Description

Product Description

DC leakage current sensor is a measuring module that converts the measured direct current into the proportional direct current or voltage signal according to the fluxgate theory and the input side is highly insulated from the output side. Typical outputs include 4-20mA, DC0-5V and DC0-10V signals. These standard signals can be acquired by various devices such as PLC, RTU, and DAS cards and used for different current monitoring applications.

Leakage current transformers surround the outlet + and - of the DC circuit. It detects output signals of sensors in circuit branches. If the insulation in circuit branches is normal, the current passing the sensor must be equal in the opposite direction. The output signal is zero. If a circuit branch is grounded, the differential current passes the leakage current transformer and the output of the sensor is not zero.

Therefore, it is possible to identify the grounded branch in the DC system by detecting output signals from circuit branches. The theory guarantees accurate line identification and prevents the influence of distributed capacitance.

Specification

Specification Rated current Power supply Rated output Aperture Precision
AHLC-LTA DC 10mA~2A ±15V 5V φ20mm 1
AHLC-EA DC 10mA~2A ±15V 5V φ40mm 1
AHLC-EB DC 10mA~2A ±15V 5V φ60mm 1

 

Dimension

Acrel DC Leakage Current Sensor Transducer for Current Differential Detection

Size
Spec.

 
Outline size(mm) Through size(mm) Mounting size(mm) Figure
W H D Φ2 Φ1 M N
AHLC-LTA 68 57 20 50 20 52 52 Fig.1
AHLC-EA 100 108 30 75 40 78 / Fig.2
AHLC-EB 120 112 30 94 60 98 / Fig.3
Notes:
1. When the hall sensor is used, in order to obtain better dynamic characteristics and sensitivity, attention must be paid to the coupling between the primary side coil and the secondary side coil. It is recommended to use a single wire and the wire completely fills the hall sensor module wire hole;
2. When the hall sensor is used, the best measurement accuracy can be obtained under the rated input current value. When the measured current is far lower than the rated current To obtain the best accuracy, multiple turns can be used for the primary side, i.e. IPNP = rated ampere-turns. In addition, the temperature of the primary side feeder shall not exceed 80 ºC;
3. The auxiliary power supply of the Hall current sensor shall not exceed ± 20% of the calibrated value when it works normally;
4. Hall current sensor shall not fall from a high place (≥ 1m) during installation and use;
5. It is unable to adjust the zero point and full degree adjustment potentiometer;
6. Auxiliary power supply needs to be configured by itself;
7. The positive and negative poles of the power supply cannot be reversed

Wiring

Acrel DC Leakage Current Sensor Transducer for Current Differential Detection
Acrel DC Leakage Current Sensor Transducer for Current Differential Detection
 

Installation Instructions

Acrel DC Leakage Current Sensor Transducer for Current Differential Detection

After Sales Service

Acrel DC Leakage Current Sensor Transducer for Current Differential Detection

Certifications

Acrel DC Leakage Current Sensor Transducer for Current Differential Detection
Acrel DC Leakage Current Sensor Transducer for Current Differential Detection

 

Company Profile

Acrel DC Leakage Current Sensor Transducer for Current Differential Detection

Acrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.
 

Acrel DC Leakage Current Sensor Transducer for Current Differential DetectionAcrel DC Leakage Current Sensor Transducer for Current Differential DetectionAcrel DC Leakage Current Sensor Transducer for Current Differential DetectionAcrel DC Leakage Current Sensor Transducer for Current Differential Detection

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now