Basic Info.
- Model NO.
- AMC16Z-ZA
- Display
- Digital
- Installation
- Direct Connected
- Usage
- Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter
- Electric Equipment
- Three-phase Three-wire
- Theory
- Static Meter
- Power Meter Connection
- Terminal
- Measured Signal
- Continuous Wave
- Type
- Power Meter
- Certification
- CE
- Customized
- Customized
- Channels
- 2
- Measure
- AC
- Communication
- RS485, Modbus-RTU
- Install
- Dinrail
- Standard
- IEC61010-1, IEC62053-22
- Transport Package
- Carton
- Specification
- AMC16Z-ZA
- Trademark
- Acrel
- Origin
- China
- HS Code
- 9028301400
- Production Capacity
- 200000
Packaging & Delivery
- Package Size
- 20.00cm * 15.00cm * 10.00cm
- Package Gross Weight
- 0.500kg
Product Description
This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for use in both new build and reconstruction and is used for critical power operations in data centers and energy management in buildings. The ideal solution for data center managers, energy or facility managers, engineers, and operational executives who are responsible for delivering power to critical applications
AMC16Z series AC branch circuit power meter can be used for building low-voltage distribution multi-circuit monitoring, especially for data center IT cabinet monitoring.
It offers class 1 (1 %) power and energy system accuracy (including 50 A to 400 A CTs) on all branch circuits.
Benefits
☆ Flexible modules can be arbitrarily assembled to accommodate any PDU solution.
★ Support new construction and renovation projects. It has the advantage of flexible assembly to respond to special power distribution detection schemes.
Advantage
☆ Applicable to any PDU solutions scheme for new construction and renovation
★ Class 0.5 system accuracy
☆ RS485 port
★ Small volume
☆ Convenient installation
★ Flexible assembly
☆ Construction convenient
Standards
☆ IEC61010-1
★ IEC62053-22 class 0.5

| Parameter | AMC16Z-ZA | AMC16Z-FAK24/48 | AMC16Z-ZD | AMC16Z-FDK24/48 | AMC16Z-KD | |
| Phase | AC | DC | AC/DC | |||
| Channel | 2 | 24/48 | 2 | 24/48 | 48 | |
| Measure | U, I, P, Q, S, F, PF, EP, EQ, | U, I, P, E | / | |||
| Neutral ground voltage, Neutral current, Total Harmonic content, 2-63rd Harmonic, Voltage phase sequence | 2-63rd Harmonic | |||||
| Bus Voltage | Rated Input | 220V AC | 48V DC, 240V DC, 336V DC | |||
| Measure Range | 85-280V AC | ±20% | ||||
| Overload | Instantaneous voltage 2 times/sec | |||||
| Current Loop | Rated Input | 5A | 50mA | 5V | ||
| Overload | Continuous current 1.2 times, Instantaneous current 10 times/second | |||||
| Frequency | 45-6Hz | / | ||||
| Accuracy | U, I: 0.2 EP: 0.5 EQ: 1 |
U, I: 0.5 E: 1 |
||||
| Auxiliary Power | signal power(≤15W) | 12-24V DC | signal power(≤15W) | 12-24V DC | 12-24V DC | |
| Insulation resistance | 100MΩ | |||||
| Power frequency withstand voltage | Power/Input Signal between ports AC 2KV/1min 50Hz | |||||
| Environment | Temperature | Working: -15ºC~55ºC Storage: -25ºC~70ºC | ||||
| Humidity | Relative humidity ≤ 93% | |||||
| Altitude | ≤ 2500m | |||||
| Switch Value Output | 2 channels 3A 250VAC / 3A 30VDC |
/ | 2 channels 3A 250VAC / 3A 30VDC |
/ | / | |
| Switch Value Input | 6 dry contacts | 24 / 48 -way wet contact | 6 dry contacts | 24 / 48 -way wet contact | 48 dry contacts | |
| Communication | RS485 Modbus-RTU | |||||
| Installation | Din-rail or Wall-mounted | |||||
| Protection level | IP20 | |||||
| Pollution level | 2 | |||||
| Safety | Insulation | The insulation resistance between all terminals and the conductive parts of the housing is not less than 100MΩ | ||||
| Pressure resistance | Signal input, relay output, rs485 communication/leakage/temperature/humidity/auxiliary power supply/switch input together, AC2KV/1min, leakage current less than 2mA, no breakdown, and flashover | |||||
| Electromagnetic Compatibility | Anti-static interference | 4 grade | ||||
| Immunity to fast transient bursts | 3 grade | |||||
| Anti-surge interference | 4 grade | |||||
| Resistant to radiofrequency electromagnetic field radiation | 3 grade | |||||
1. 2DO
2. Standby current
3. Standby voltage
4. Main current
5. Main voltage
6. Communication & 24V DC power output
7. Leakage current
8. Temperature and humidity
9. 6-channel passive DI
2. Standby current
3. Standby voltage
4. Main current
5. Main voltage
6. Communication & 24V DC power output
7. Leakage current
8. Temperature and humidity
9. 6-channel passive DI
Characteristics
☆ High integration, used for monitoring main and standby circuit, 2-channel 3 phase AC inlet.
★ Output 24V to supply power to the outlet module, which can operate without extra power supply and relay.
☆ IEC class 1 metering
★ VIA(mA)/ P/ Kwh class 0.5, Q/ Kvarh class 1.
☆ Branch power and energy measurements fully meet ANSI and IEC Class 1 accuracy requirements.
★ PQ: Basic power quality data is obtained by measuring the percentage of total harmonic distortion through voltage and current.
☆ Design fits any PDU or RPP solution.
★ Support new construction and renovation projects.
☆ Communicate with various systems:1-channel RS485 port, Modbus-RTU.
★ Compatible with AMC precision distribution management system.
☆ It is easy to centrally collect equipment data and turn it into useful decision information.
☆ High integration, used for monitoring main and standby circuit, 2-channel 3 phase AC inlet.
★ Output 24V to supply power to the outlet module, which can operate without extra power supply and relay.
☆ IEC class 1 metering
★ VIA(mA)/ P/ Kwh class 0.5, Q/ Kvarh class 1.
☆ Branch power and energy measurements fully meet ANSI and IEC Class 1 accuracy requirements.
★ PQ: Basic power quality data is obtained by measuring the percentage of total harmonic distortion through voltage and current.
☆ Design fits any PDU or RPP solution.
★ Support new construction and renovation projects.
☆ Communicate with various systems:1-channel RS485 port, Modbus-RTU.
★ Compatible with AMC precision distribution management system.
☆ It is easy to centrally collect equipment data and turn it into useful decision information.


| EMC | LVD |
Acrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.
Send your message to this supplier
People who viewed this also viewed
Product Groups
Find Similar Products By Category
- Supplier Homepage
- Products
- Application
- Branch Circuit Monitor for Data Center
- Internet Data Center AC Incoming Circuit Monitor Meter Module
Related Categories
Hot Searches
More