Internet Data Center AC Incoming Circuit Monitor Meter Module

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Years
Still deciding? Get samples of US$ 91/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Arabic
Experienced Team
The supplier has 42 foreign trading staff(s) and 33 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (18)
  • Internet Data Center AC Incoming Circuit Monitor Meter Module
  • Internet Data Center AC Incoming Circuit Monitor Meter Module
  • Internet Data Center AC Incoming Circuit Monitor Meter Module
  • Internet Data Center AC Incoming Circuit Monitor Meter Module
  • Internet Data Center AC Incoming Circuit Monitor Meter Module
  • Internet Data Center AC Incoming Circuit Monitor Meter Module
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Module
  • Dimension
  • Networking
  • Installation Instructions
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
AMC16Z-ZA
Installation
Direct Connected
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter
Electric Equipment
Three-phase Three-wire
Theory
Static Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Power Meter
Certification
CE
Customized
Customized
Channels
2
Measure
AC
Communication
RS485, Modbus-RTU
Install
Dinrail
Standard
IEC61010-1, IEC62053-22
Transport Package
Carton
Specification
AMC16Z-ZA
Trademark
Acrel
Origin
China
HS Code
9028301400
Production Capacity
200000

Packaging & Delivery

Package Size
20.00cm * 15.00cm * 10.00cm
Package Gross Weight
0.500kg

Product Description

Product Description

This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for use in both new build and reconstruction and is used for critical power operations in data centers and energy management in buildings. The ideal solution for data center managers, energy or facility managers, engineers, and operational executives who are responsible for delivering power to critical applications

AMC16Z series AC branch circuit power meter can be used for building low-voltage distribution multi-circuit monitoring, especially for data center IT cabinet monitoring.
It offers class 1 (1 %) power and energy system accuracy (including 50 A to 400 A CTs) on all branch circuits.
 
Benefits
☆ Flexible modules can be arbitrarily assembled to accommodate any PDU solution.
★ Support new construction and renovation projects. It has the advantage of flexible assembly to respond to special power distribution detection schemes.
Advantage
☆ Applicable to any PDU solutions scheme for new construction and renovation
★ Class 0.5 system accuracy
☆ RS485 port
★ Small volume
☆ Convenient installation
★ Flexible assembly
☆ Construction convenient
Standards
☆ IEC61010-1
★ IEC62053-22 class 0.5

Product Parameters

Internet Data Center AC Incoming Circuit Monitor Meter Module

Parameter AMC16Z-ZA AMC16Z-FAK24/48 AMC16Z-ZD AMC16Z-FDK24/48 AMC16Z-KD
Phase AC DC AC/DC
Channel 2 24/48 2 24/48 48
Measure U, I, P, Q, S, F, PF, EP, EQ,  U, I, P, E /
Neutral ground voltageNeutral currentTotal Harmonic content, 2-63rd Harmonic, Voltage phase sequence 2-63rd Harmonic
Bus Voltage Rated Input 220V AC 48V DC, 240V DC, 336V DC
Measure Range 85-280V AC ±20%
Overload Instantaneous voltage 2 times/sec
Current Loop Rated Input 5A 50mA 5V
Overload Continuous current 1.2 times, Instantaneous current 10 times/second
Frequency 45-6Hz /
Accuracy U, I: 0.2
EP: 0.5
EQ: 1
U, I: 0.5
E: 1
Auxiliary Power signal power(≤15W) 12-24V DC signal power(≤15W) 12-24V DC 12-24V DC
Insulation resistance 100MΩ
Power frequency withstand voltage Power/Input Signal between ports AC 2KV/1min 50Hz
Environment Temperature Working: -15ºC~55ºC  Storage: -25ºC~70ºC
Humidity Relative humidity ≤ 93%
Altitude ≤ 2500m
Switch Value Output 2 channels
3A 250VAC / 3A 30VDC
/ 2 channels
3A 250VAC / 3A 30VDC
/ /
Switch Value Input 6 dry contacts 24 / 48 -way wet contact 6 dry contacts 24 / 48 -way wet contact 48 dry contacts
Communication RS485  Modbus-RTU
Installation Din-rail or Wall-mounted
Protection level IP20
Pollution level 2
Safety Insulation The insulation resistance between all terminals and the conductive parts of the housing is not less than 100MΩ
Pressure resistance Signal input, relay output, rs485 communication/leakage/temperature/humidity/auxiliary power supply/switch input together, AC2KV/1min, leakage current less than 2mA, no breakdown, and flashover
Electromagnetic Compatibility Anti-static interference 4 grade
Immunity to fast transient bursts 3 grade
Anti-surge interference 4 grade
Resistant to radiofrequency electromagnetic field radiation 3 grade

Module

Internet Data Center AC Incoming Circuit Monitor Meter Module
1. 2DO
2. Standby current
3. Standby voltage
4. Main current
5. Main voltage
6. Communication & 24V DC power output
7. Leakage current
8. Temperature and humidity
9. 6-channel passive DI
Characteristics
☆ High integration, used for monitoring main and standby circuit, 2-channel 3 phase AC inlet.
★ Output 24V to supply power to the outlet module, which can operate without extra power supply and relay.
☆ IEC class 1 metering
★ VIA(mA)/ P/ Kwh class 0.5, Q/ Kvarh class 1.
☆ Branch power and energy measurements fully meet ANSI and IEC Class 1 accuracy requirements.
★ PQ: Basic power quality data is obtained by measuring the percentage of total harmonic distortion through voltage and current.
☆ Design fits any PDU or RPP solution.
★ Support new construction and renovation projects.
☆ Communicate with various systems:1-channel RS485 port, Modbus-RTU.
★ Compatible with AMC precision distribution management system.
☆ It is easy to centrally collect equipment data and turn it into useful decision information.
Internet Data Center AC Incoming Circuit Monitor Meter Module

Dimension

Internet Data Center AC Incoming Circuit Monitor Meter Module

Networking

Internet Data Center AC Incoming Circuit Monitor Meter Module
Internet Data Center AC Incoming Circuit Monitor Meter Module

Installation Instructions

Internet Data Center AC Incoming Circuit Monitor Meter Module

Certifications

Internet Data Center AC Incoming Circuit Monitor Meter Module
Internet Data Center AC Incoming Circuit Monitor Meter Module
 
EMC LVD

 

Company Profile

Internet Data Center AC Incoming Circuit Monitor Meter Module
Internet Data Center AC Incoming Circuit Monitor Meter Module
Acrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.
Internet Data Center AC Incoming Circuit Monitor Meter Module

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now