Amc16-Dett DC Multichannel Energy Meter for Tower Base Station

Product Details
Customization: Available
Interface: RS485
Protocol: Yd/T1363.3-2014
Still deciding? Get samples of US$ 60/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Arabic
Experienced Team
The supplier has 42 foreign trading staff(s) and 33 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (18)
  • Amc16-Dett DC Multichannel Energy Meter for Tower Base Station
  • Amc16-Dett DC Multichannel Energy Meter for Tower Base Station
  • Amc16-Dett DC Multichannel Energy Meter for Tower Base Station
  • Amc16-Dett DC Multichannel Energy Meter for Tower Base Station
  • Amc16-Dett DC Multichannel Energy Meter for Tower Base Station
  • Amc16-Dett DC Multichannel Energy Meter for Tower Base Station
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Panel
  • Wiring
  • Recommend Hall Sensor
  • Networking
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
AMC16-DETT
Installation
DIN 35 mm
Power Supply Output
+12V/100mA, -12V/50mA
Transport Package
Carton
Specification
AMC16-DETT
Trademark
Acrel
Origin
China
HS Code
9028301400
Production Capacity
200000

Packaging & Delivery

Package Size
17.00cm * 15.00cm * 13.00cm
Package Gross Weight
0.500kg

Product Description

 

Product Description

Base station dedicated DC energy meter AMC16-DETT is specially designed for base stations where have sharing requirements, and switch power supply is without the function of sub-user metering.The meter could measure6 circuits DC energy, and supply working current to the matched hall sensors. Meanwhile, it can realize zero drift calibration by upper computer software.have the functions of telemetering,teleindication,teleadjusting, metering at real time,energy quality abnormal alarm, data storage and processing, data interaction.

Specification

 
Amc16-Dett DC Multichannel Energy Meter for Tower Base Station

Communication

Single channel RS485 communication protocol

Standard or customized

Rated U and I:Total 200A/5V

Accuracy 1%In≤I≤10%In error±2.5%;I>10%In error±2%

 

Power consumption:≤2W( no hall power supply output)

Voltage range:-40V~-60VDC

Power supply output

+12V/100Ma, -12V/50mA

 

Power consumption

≤2W( no hall power supply output)

 

Dimension(L*W*H):89.7*87.8*52mm

 

Installation:DIN 35 mm

Clock:≤0.5S/d(23ºC), ≤1S/d(-20ºC-60ºC)

 

Current:1.2 times continued

Amc16-Dett DC Multichannel Energy Meter for Tower Base Station

 

Panel


Amc16-Dett DC Multichannel Energy Meter for Tower Base Station
 

Wiring

Amc16-Dett DC Multichannel Energy Meter for Tower Base Station
Amc16-Dett DC Multichannel Energy Meter for Tower Base Station
 

Recommend Hall Sensor

Amc16-Dett DC Multichannel Energy Meter for Tower Base Station
Amc16-Dett DC Multichannel Energy Meter for Tower Base Station
Amc16-Dett DC Multichannel Energy Meter for Tower Base Station
 
AHKC-EKA (50A/5V) AHKC-EKB (100A/5V) AHKC-K (200A/5V)



FAQ


Q:The measurement of the metering module is inaccurate.
A:Check input whether the polarity and direction of the input voltage and current wiring are correct;Whether the direction of the primary current of the Hall sensor is correct; Whether the output signal of the Hall sensor matches the input signal required by the module; Check whether the output negative pole of the voltage output Hall sensor is connected to the module GND.
 
Q:Communication is abnormal.
A:Check communication whether the communication cable is normal; check whether the communication terminals A and B are staggered; check whether the address of the module is set correctly and whether the communication baud rate is set correctly; if the communication of multiple modules is not normal, first try whether the single-machine communication is normal.
 
Q:The metering module cannot be displayed normally.
A:Check whether it is caused by insufficient load capacity due to the built-in power supply to the hall sensor. Change the external switching power supply to power the hall.
 

Networking

Amc16-Dett DC Multichannel Energy Meter for Tower Base Station

Amc16-Dett DC Multichannel Energy Meter for Tower Base Station

Certifications

Amc16-Dett DC Multichannel Energy Meter for Tower Base Station

Company Profile

Amc16-Dett DC Multichannel Energy Meter for Tower Base Station

Acrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.
 

Amc16-Dett DC Multichannel Energy Meter for Tower Base Station
Amc16-Dett DC Multichannel Energy Meter for Tower Base Station
Amc16-Dett DC Multichannel Energy Meter for Tower Base Station
Amc16-Dett DC Multichannel Energy Meter for Tower Base Station


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier