• Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower
  • Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower
  • Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower
  • Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower
  • Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower
  • Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower

Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower

Interface: RS485
Protocol: Yd/T1363.3-2014
Protection Level: IP20
Samples:
US$ 61.6/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower pictures & photos
Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower
US $61.6-61.61 / Piece
Min. Order: 1 Piece
Diamond Member Since 2020

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Specification
  • Panel
  • Wiring
  • Recommend Hall Sensor
  • Networking
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
AMC16-DETT
DC Rated Voltage
1 Channel: -48VDC
Application
Base Stations and Data Center
Transport Package
Carton
Specification
AMC16-DETT
Trademark
Acrel
Origin
China
HS Code
9028301400
Production Capacity
200000

Packaging & Delivery

Package Size
17.00cm * 15.00cm * 13.00cm
Package Gross Weight
0.500kg

Product Description

AMC16-DETT Base Station 6 channel DC Energy Meter For telecom Tower 

Product Description

Base station dedicated DC energy meter AMC16-DETT is specially designed for base stations where have sharing requirements, and switch power supply is without the function of sub-user metering.The meter could measure6 circuits DC energy, and supply working current to the matched hall sensors. Meanwhile, it can realize zero drift calibration by upper computer software.have the functions of telemetering,teleindication,teleadjusting, metering at real time,energy quality abnormal alarm, data storage and processing, data interaction.Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom TowerFeatures of AMC16-DETT Base Station 6 channel DC Energy Meter For telecom Tower

1. AMC16-DETT Base Station 6 channel DC Energy Meter For telecom Tower can measure the DC electric energy of the six circuits, and can provide the working current for the matching Hall sensor;

2. AMC16-DETT Base Station 6 channel DC Energy Meter For telecom Tower can monitor equipment system time, total voltage, total output current, total power, total electric energy, and voltage, current, power and electric energy of each branch;

3. AMC16-DETT Base Station 6 channel DC Energy Meter For telecom Tower can have alarm function, LED indicator light display, RS485 communication,and support broadcasting for calibration time.

Specification

 
Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower

Communication

Single channel RS485 communication protocol

Standard or customized

Rated U and I:Total 200A/5V

Accuracy 1%In≤I≤10%In error±2.5%;I>10%In error±2%

 

Power consumption:≤2W( no hall power supply output)

Voltage range:-40V~-60VDC

Power supply output

+12V/100Ma, -12V/50mA

 

Power consumption

≤2W( no hall power supply output)

 

Dimension(L*W*H):89.7*87.8*52mm

 

Installation:DIN 35 mm

Clock:≤0.5S/d(23ºC), ≤1S/d(-20ºC-60ºC)

 

Current:1.2 times continued

Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower
Technical parameter Index
input DC rated voltage 1 channel:    -48VDC
DC current 6  channels  hall  sensors:  total  200A/5V,  China  Telecom,  China Mobile,  China  Unicom  and  the  1st  channel  reserve  50A/5V,  2nd
channel reserve 100A/5V.
Commercial power monitoring 1 channel: 0-5VDC
Overload capacity Voltage:1.2times continued,2 times continued 1s;
Current: 1.2 times continued,10 times continued 1s.
Accuracy (superposition hall sensors) 1%In≤I≤10%In    error±2.5%; I>10%In error±2%
Measurement resolution Voltage output accuracy 0.01V;    current output accuracy 0.01A;
power output accuracy 0.01kw; energy output accuracy 0.01kwh
functions Basic function Monitor  device  system  time,  total  voltage,  output  total  current, power, energy, each channel voltage, current, power, energy; LED
indicator display;485 communication
Metering function Start current: under rated voltage, when the load current value of the  meter  doesn't  exceed  1%  of  the  max.  current,  the  meter starts.
Shunt  running  current:  when  there  is  no  current  in  the  current circuit of the meter, and 85%-125%of the rated voltage is applied on  the  voltage  circuit,  the  calculator  shall  not  have  more  than one digital change
Alarm function DC  voltage  output  low  alarm,DC  voltage  output  high  alarm,one power down alarm, module voltage loss alarm, metering branch error  alarm,  internal  program  error  alarm,  clock  error  alarm,memory failure alarm, AC input power failure alarm
Timing function support  broadcast  timing,  could  remote  timing  to  the  meter through RS485 communication.
Communication Single channel RS485, baudrate 9600bps, can be set to 1200BPS, 2400bps, 4800bps.Communication protocol: standard or custmized
Hall sensor power
supply
Power supply output:+12V/100Ma, -12V/50mA
Clock accuracy ≤0.5S/d(23ºC),  ≤1S/d(-20ºC-60ºC),
Auxiliary power supply Voltage range -40V~-60VDC
Power consumption Whole device≤2W( no hall power supply output)
Storage It has the storage function of historical power data and historical
alarm information, and the memory is 2MB
Insulation resistance ≥40MΩ
environment Temperature Working : -20ºC~+60ºC; storage:-40ºC~+70ºC
Humidity ≤98% no condensation, no corrosive gas place
Altitude ≤4000m
Protection level IP20
Material flame retardent Terminal  glow  wire  temperature  960ºC±10ºC ,shell  glow  wire temperature 6500ºC±15ºC
installation Standard 35mm din rail
Lightning protection Voltage input
(differential mode)
Peak value 5kA
Auxiliary power supply
(differential mode)
Peak value 5kA
 

Panel


Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower
 

 

Wiring

Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower

Recommend Hall Sensor

 
FAQ


Q:The measurement of the metering module is inaccurate.
A:Check input whether the polarity and direction of the input voltage and current wiring are correct;Whether the direction of the primary current of the Hall sensor is correct; Whether the output signal of the Hall sensor matches the input signal required by the module; Check whether the output negative pole of the voltage output Hall sensor is connected to the module GND.
 
Q:Communication is abnormal.
A:Check communication whether the communication cable is normal; check whether the communication terminals A and B are staggered; check whether the address of the module is set correctly and whether the communication baud rate is set correctly; if the communication of multiple modules is not normal, first try whether the single-machine communication is normal.
 
Q:The metering module cannot be displayed normally.
A:Check whether it is caused by insufficient load capacity due to the built-in power supply to the hall sensor. Change the external switching power supply to power the hall.
 

Networking

Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower

Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower

Certifications

Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower
 

Company Profile

Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower

Acrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.
 

Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower
Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower
Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower
Amc16-Dett Base Station 6 Channel DC Energy Meter for Telecom Tower


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now