With the rapid development of data centers, the energy consumption of data centers has become more and more prominent, and the energy management and power supply and distribution design of data centers have become hot issues.
An efficient and reliable data center power distribution system solution is an effective way to improve the Power Usage Effectiveness (PUE) of the data center and reduce the energy consumption of equipment.
The AMC series precision power distribution monitoring solution is a complete solution designed for the power distribution monitoring requirements of the column head cabinet in the Internet Data Center (IDC).
It is necessary to real-time monitor and centralize power consumption in the data center and data can be displayed on HMI, and uploaded to the power and environment monitoring system by RS485 on the touch screen and realize real-time monitoring of the whole power distribution system. At the same time, it can realize energy efficiency analysis to reduce energy consumption.
1) Incoming line and outgoing line circuits independent monitoring modules;
2) Can measure up to 2 incoming line circuits and up to 192 outgoing line circuits current, voltage, power, energy, and power quality;
3) Data centralized monitoring and display by HMI and data is uploaded to power and environment monitoring system through RS485;
4) For high voltage DC 240V or 336V system, insulation monitoring module can be added to monitor ground insulation resistance of the main bus;
5) DC24V power supply for touch screen and outgoing line monitoring module(power supply from main module output );
6) Communication: monitoring device by RS485, touch screen by RS485 or RJ45;
7) Certificate: CE.
Website: http://116.236.149.165:8090/DataCenter/login
Account: guest
Password: 123456
Product Name | Image | Function |
AMC16Z-ZA Data Center Monitor Device |
☆ Designed specifically for the power supply management of server in the data center ★ A+B independent 2 channels three-phase inlet ☆ U, I, P, Q, S, PF, kWh, kvarh ★ 2nd-63rd Harmonic |
|
AMC16Z-FAK48 Data Center Monitor Device |
☆ Designed specifically for the power supply management of server in the data center ★ A+B independent 24 circuits(48 in total) ☆ U, I, P, Q, S, PF, kWh, kvarh ★ 2nd-31st Harmonic ☆ kWh Class 0.5 DIN 35 mm |
|
AMC16Z-ZD DC Incoming Line Monitoring Module |
☆ DIN 35mm ★ Measurement: A+B independent circuits, 6DI 2DO,1 temp. and humidity. ☆ With DC 24V output power supply for outgoing line module and touch screen. ★ Communication: RS485 Modbus RTU |
|
AMC16Z-FDK24/48 DC Outgoing Line Monitoring Module |
☆ DIN 35mm ★ Can measure up to 48 circuits DC outgoing line ☆ DC24V power supply ★ Communication: RS485 Modbus RTU |
|
AMC16Z-ZJY DC Incoming Line Insulation Monitoring Module |
☆ DIN 35mm ★ Measure A+B independent DC circuit ground insulation resistance of the main bus ☆ DC24V power supply ★ Communication: RS485 Modbus RTU |
|
AMC16Z-FJY DC Outgoing Line Insulation Monitoring Module |
☆ DIN 35mm ★ Measure 24 circuits ground insulation resistance of DC outgoing line |
|
AKH-0.66/W Current Sensor | ☆ Current Ratio: 50A/50mA & 100A/50mA ★ Accuracy: 0.2 grade ☆ Load: 10 VA/Ω ★ Inner Aperture: 9mm & 15mm ☆ Installation: Din-rail |
|
AKH-EMS | ☆ Current Ratio: 50A/10mA ★ Accuracy: 0.2 grade ☆ Load: 10 VA/Ω ★ Installation: Din-rail |