Customization: | Available |
---|---|
Type: | Electromagnetic |
Output Signal Type: | Analog Output |
Still deciding? Get samples of US$ 38.77/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
BD series electric transducer is a kind of device which can isolate and transmit electric parameters such as current, voltage frequency, power, power factor or temperature, resistance, and so on non-electrical parameters, into linear DC analog signal or digital signal. They can directly connect with the pointer table, digital meters also can be connected with automatic control devices (eg PLC), a variety of A / D converters, and the computer system.
Specifications | BD-AI BD-AV |
BD-F | BD-PF | BD-3I3 BD-3(4)V3 |
BD-3(4)P BD-3(4)Q |
BD-3(4)E | ||
Phase&Wiring | 1P2W | YES | Optional | Optional | Optional | Optional | Optional | |
3P3W | / | / | Optional | Optional | Optional | Optional | ||
3P4W | / | / | Optional | Optional | Optional | Optional | ||
Input | Voltage | Direct L-L | Up to 480V AC | |||||
Direct L-N | Up to 276V AC | |||||||
With external PT | YES | YES | YES | YES | YES | YES | ||
Current | Direct | Up to 5A AC | ||||||
With external CT | YES | YES | YES | YES | YES | YES | ||
Measuring | Voltage | Optional | / | / | Optional | |||
Current | / | / | Optional | Optional | Optional | |||
Active/Reactive Power | / | / | / | / | Optional | Optional | ||
Apparent Power | / | / | / | / | Optional | Optional | ||
Power Factor | / | / | / | Optional | Optional | |||
Frequency | / | / | / | Optional | Optional | |||
Energy Metering | ±KWh | / | / | / | / | / | Optional | |
Accuracy Class | 0.50% | |||||||
communication | Interface:RS485 Protocol:Modbus-RTU | Optional | Optional | / | Optional | Optional | Optional | |
Analog Output | DC 0-5V,0-10,0-20mA,4-20mA | |||||||
Pulse Output | / | / | / | / | / | YES | ||
Dimensions(mm) | Housing(W×H×D) | 138×76×24 | 119×75×55 | 119×75×55 | 112×110×75 | 112×110×75 | 112×110×75 | |
Auxiliary Power | AC/DC 85-265V,DC 24V,DC48V | |||||||
Temperature | Operation | -10 to +55ºC | ||||||
Storage | -25 to +70ºC | |||||||
Humidity | Up to 95%,no condensing | |||||||
Installation | (Rail)DIN35, fix on cubicle with screws | |||||||
Standards | GB/T 13850 |
Type | BD-DI BD-DV |
BD-AI BD-AV |
BD-3I3 BD-3V3 BD-4V3 |
BD-3P BD-3Q BD-3P/Q/I |
BD-4P BD-4Q BD-4P/Q/I |
BD-3E BD-4E BD-4EA |
BD-PF BD-F |
|
Class | 0.5 | |||||||
Input | Signal | DC 4-20mA | AC 0-1A | AC 1A | ||||
DC 0-20mA | AC 0-5A | AC 5A | ||||||
DC 0-10V | AC 0-120V | AC 100V | ||||||
DC 0-75mA | AC 0-300V | AC 220V | ||||||
DC 0-300V | AC 0-500V | AC 380V | ||||||
Overload | Current:1.2 times everiasting, 10 times/1s | |||||||
Voltage:1.2 times everiasting, 2 times/1s | ||||||||
Frequency | 45Hz-65Hz | |||||||
Output | Signal | DC 4-20mA,0-20mA,0-5V,0-10V | ||||||
Load | Current Output≤600Ω Voltage Output≥1000Ω | |||||||
Selected function | / | RS485 | / | RS485 communication | ||||
Power supply | AC 85V-265V/DC 100V-350V or DC24V or DC 48V | |||||||
Temperature drift coefficient | Class 0.5≤200ppm/ºC, class 0.2≤100ppm/ºC | |||||||
Response time | <400ms | |||||||
Insulation resistance | ≥100MΩ | |||||||
Power frequency withstand voltage | the value of alternating current between the power supply, input, and output:2kV/1min | |||||||
Environment | Temperature | operating temperature:-10 to +55ºC storage temperature: -25 to +70ºC |
||||||
Humidity | ≤95%RH, no dew, no aggressive gas | |||||||
Altitude | ≤2500m | |||||||
Installation method | TS35mm rail designed or screw |