Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 1 Years |
Still deciding? Get samples of US$ 129.23/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
With the rapid development of data centers, the energy consumption of data centers has become more and more prominent, and the energy management and power supply and distribution design of data centers have become hot issues.
An efficient and reliable data center power distribution system solution is an effective way to improve the Power Usage Effectiveness (PUE) of the data center and reduce the energy consumption of equipment.
The AMC series precision power distribution monitoring solution is a complete solution designed for the power distribution monitoring requirements of the column head cabinet in the Internet Data Center (IDC).
AMC100 series precision power distribution monitoring solution is a complete solution designed for the power distribution monitoring requirements of data center column cabinets.
It can monitor the full electrical parameters of A+B two incoming lines and 192 outgoing lines, input and output switch values, and the status of the lightning arrester in real-time, and realizes a high degree of integration of monitoring loops in the volume of traditional instruments.
The device is mainly composed of the main circuit module, a shunting module, a current transformer, and a touch display screen. This series of products can be matched with din-rail type current transformers and plug-in installation of current terminals, which greatly improves the wiring efficiency.
Parameter | AMC100-ZA | AMC100-FAK30/48 | AMC100-FA30(48) | AMC100-ZD | AMC100-FDK30/48 | AMC100-FD30(48) | |
Phase | AC | DC | |||||
Channel | 2 | 30/48 | 30/48 | 2 | 30/48 | 30/48 | |
Measure | U, I, P, Q, S, F, PF, EP, EQ, | U, I, P, E | |||||
Neutral ground voltage, Neutral current, Total Harmonic content, 2-63rd Harmonic, Voltage phase sequence | 2-63rd Harmonic | ||||||
Bus Voltage | Rated Input | 220V AC | 48V DC, 240V DC, 336V DC | ||||
Measure Range | 85-280V AC | ±20% | |||||
Overload | Instantaneous voltage 2 times/sec | ||||||
Current Loop | Rated Input | 5A | 50mA | 50mA | 5V | ||
Overload | Continuous current 1.2 times, Instantaneous current 10 times/second | ||||||
Frequency | 45-6Hz | / | |||||
Accuracy | U, I: 0.2 EP: 0.5 EQ: 1 |
U, I: 0.5 E: 1 |
|||||
Auxiliary Power | signal power(≤15W) | 12-24V DC | 12-24V DC | signal power(≤15W) | 12-24V DC | 12-24V DC | |
Insulation resistance | 100MΩ | ||||||
Power frequency withstand voltage | Power/Input Signal between ports AC 2KV/1min 50Hz | ||||||
Environment | Temperature | Working: -15ºC~55ºC Storage: -25ºC~70ºC | |||||
Humidity | Relative humidity ≤ 93% | ||||||
Altitude | ≤ 2500m | ||||||
Switch Value Output | 4 channels 3A 250VAC / 3A 30VDC |
/ | / | 4 channels 3A 250VAC / 3A 30VDC |
/ | / | |
Switch Value Input | 8 dry contacts | 30 / 48 -way wet contact | / | 8 dry contacts | 30 / 48 -way wet contact | / | |
Communication | RS485 Modbus-RTU | ||||||
Installation | Din-rail or Wall-mounted | ||||||
Protection level | IP20 | ||||||
Pollution level | 2 | ||||||
Safety | Insulation | The insulation resistance between all terminals and the conductive parts of the housing is not less than 100MΩ | |||||
Pressure resistance | Signal input, relay output, rs485 communication/leakage/temperature/humidity/auxiliary power supply/switch input together, AC2KV/1min, leakage current less than 2mA, no breakdown, and flashover | ||||||
Electromagnetic Compatibility | Anti-static interference | 4 grade | |||||
Immunity to fast transient bursts | 3 grade | ||||||
Anti-surge interference | 4 grade | ||||||
Resistant to radiofrequency electromagnetic field radiation | 3 grade |
DC Outgoing Line Hall Sensor |
EMC | LVD |