After-sales Service: | Yes |
---|---|
Warranty: | 2 Years |
Display: | Digital |
Installation: | Direct Connected |
Usage: | Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter |
Electric Equipment: | Three-phase Three-wire |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
AMB series products are designed for track busway monitoring and real-time monitoring energy consumption and power quality of end load. Data can be uploaded to the monitoring system by local touch screen through RS485 and it can realize real-time monitoring of the whole power distribution system. At the same time, it can monitor real-time temperature at the busway connector and plug-in box interface to ensure the safe and reliable operation of the busway.
Model
|
AMB100A
|
AMB110A
|
|
Measurement parameters
|
voltage, current, frequency, active power, reactive power, power factor, active power, reactive power
|
||
max demand, zero line current, neutral current, zero ground voltage
|
|||
2-63st harmonics
|
|||
1 channel leakage current,1 channel humidity
|
|||
2 DI 2 DO
|
|||
8 channel temperature
|
4 channel temperature
|
||
Voltage
|
Rated voltage
|
3x220VAC or 3x380VAC
|
|
Measurement range
|
±20%
|
||
Overload
|
Instantaneous voltage 2 times/second
|
||
Current
|
CT
|
5A/2.5mA
|
100A/20mA
|
Range
|
1%~120%
|
||
overload
|
Duration 1.2 times, instantaneous 10 times/second
|
||
Input frequency
|
45~60Hz
|
||
Accuracy
|
Class 0.5:Voltage/current/active power/active energy
|
||
Class 1:reactive power/reactive energy
|
|||
Auxiliary power supply
|
Power on by system voltage
|
||
Communication
|
RS485/Modbus-RTU
|
||
Optional communication
|
LoRa communication
|
||
Installation
|
DIN 35mm din rail
|
1. AMB100 or AMB110 is usually installed in the busbar start box and plug-in box.
2. Measurement: AC or DC busbar voltage, current, harmonics, and other parameters.
3. Realize temperature monitoring of the busbar plug interface.
4. AMB200 is usually installed at the connector of the dense AC busbar and can monitor temperature and humidity at the connector.
5. Communication: LoRa or RS485
Model | FUNCTIONS | OPTIONAL |
AMB100-A | three-phase AC electrical data monitoring, 2nd-63rd harmonic monitoring 1 channel leakage current, 8 channels temperature, 1 channel humidity, max. demand, Ln zero-field voltage, 2DI/2DO |
/W(LORA) |
AMB110-A | three-phase AC electrical data monitoring, 2nd-63rd harmonic monitoring 1 channel leakage current, 4 channels temperature, 1 channel humidity, max. demand, Ln zero-field voltage, 2DI |
/W(LORA) |
AMB100-D | DC electrical data monitoring, 1 channel leakage current, 4 channels temperature, 1 channel humidity, 2DI/2DO |
/W (LORA) |
AMB110-D | DC electrical data monitoring, 1 channel leakage current, 2 channels temperature, 1 channel humidity, 2DI |
/W(LORA) |