Ground Fault Location in Ungrounded System

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 2 Year
Still deciding? Get samples of US$ 5708/Set
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Arabic
Experienced Team
The supplier has 42 foreign trading staff(s) and 33 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (18)
  • Ground Fault Location in Ungrounded System
  • Ground Fault Location in Ungrounded System
  • Ground Fault Location in Ungrounded System
  • Ground Fault Location in Ungrounded System
  • Ground Fault Location in Ungrounded System
  • Ground Fault Location in Ungrounded System
Find Similar Products
  • Overview
  • Product Description
  • Networking
  • Specification
  • Rated Products
  • Onsite Photo
  • After Sales Service
  • Company Profile
Overview

Basic Info.

Model NO.
GGF
Frequency Range
45-60Hz
Type
Function Signal Generator
Channel
1
Display
Digital
Voltage
DC24V
Interface
Can
Protocol
Customized
Location Voltage
Less Than 25V
Location Current
Less Than 1mA
Transport Package
Carton
Specification
AIL
Trademark
Acrel
Origin
China
HS Code
9030849000
Production Capacity
200000

Packaging & Delivery

Package Size
20.00cm * 15.00cm * 10.00cm
Package Gross Weight
50.000kg

Product Description

 

Product Description

The medical isolation power supply cabinet is a power distribution cabinet with a local IT system designed for the power supply requirements of medical Class 2 places. The IT system is equipped with an insulation monitoring device to monitor the insulation status of the system, and each output circuit adopts a circuit breaker with short-circuit protection function; Other system output circuits use circuit breakers with leakage protection function.
According to the different places of use, the products are divided into two categories: GGF-O series isolation power cabinets for operating rooms and GGF-I series ICU/CCU isolation power cabinets, which can well meet the needs of various operating rooms and intensive care units. Requirements for power safety and reliability, and compliance with IEC60364--10:2002 standard.

 

 

Networking

Ground Fault Location in Ungrounded SystemGround Fault Location in Ungrounded System

 

Specification

Ground Fault Location in Ungrounded System

Parameters GGF-IXG GGF-IXQ GGF-IXF
Rated Voltage 220V AC
Rated Capacity 3.15 / 5 / 6.3 / 10KVA ---
Rated Frequency 50/60HZ
Distribution circuit IT System:4 or 5 channels AC220V(can be customized)
Protection level IP31 IP34D
Installation Grounded Embedded
Communication RS485 interface, Modbus-RTU protocol
 

Rated Products

Ground Fault Location in Ungrounded System AITR Series Hospital Grade Isolation Transformers
☆ Capacity: 8 KVA
☆ Noise Level: <40dB
☆ Insulation Class: H
☆ Short Circuit Voltage ≤ 3%
☆ No-load Output Current ≤ 3%
☆ Inrush Current ≤ 12 In
☆Leakage Current <0.2mA
☆ Efficiency >96%
Ground Fault Location in Ungrounded System AIM-M100 Line Isolation Monitor
☆ Certificate: CE, IEC
☆ Communication: RS485
☆ Monitoring Ground Insulation
☆ Monitoring Transformer Load and Temperature
☆ Alarm Relay Output
Ground Fault Location in Ungrounded System AKH-0.66P26 Protection Current Transformer
☆ Current Ratio: 2000:1
☆ Maximum measurable current: 50A
☆ Accuracy: 0.5%
☆ Isolation Voltage: 5000Vac
Ground Fault Location in Ungrounded System

ACLP10-24 DC Switching Power Supply

☆ Input: AC220V(±10%)
☆ Output: DC24V(±5%)
☆ Power: 3W
Ground Fault Location in Ungrounded System AID150 Remote Annunciator
 ☆Certificate: CE
☆ Communication: RS485
☆ Auxiliary Power Voltage: DC 24V
☆ Alarm: Insulation, Overload, Overtemp
☆ Display: LCD
Ground Fault Location in Ungrounded System HDR-60-24 DC Switching Power Supply 
☆ Input: AC100-240V
☆ Output: DC24V
☆ Power: 60W

 

Onsite Photo

 

Ground Fault Location in Ungrounded System

After Sales Service

Ground Fault Location in Ungrounded System

 

Company Profile

Acrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.
 
Ground Fault Location in Ungrounded System


 