Type: | Hall Type |
---|---|
Output Signal Type: | Analog Output |
Accuracy Grade: | 1.0G |
Samples: |
---|
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
Rated current input: 0~(50-5000)A
Rated output: 5V / 4V / 4-20mA
Aperture: 20mm/40mm/55mm/etc
Power supply: ±15V / 12V / 24V
Small package size
Low power consumption
Extended measuring range
Split Type; Easy installation
Type | Rated current | Rated output | Measuring Aperture | Power Supply |
AHKC-EKA | 0-(50-500)A | 5V/4V | Φ20mm | ±15V |
AHKC-EKAA | DC 0-(50-500)A | DC4-20mA | Φ20mm | 12V/24V |
AHKC-EKDA | AC 0-(50-500)A | DC4-20mA | Φ20mm | 12V/24V |
AHKC-EKB | 0-(200-1000)A | 5V/4V | Φ40mm | ±15V |
AHKC-EKBA | DC 0-(200-1000)A | DC4-20mA | Φ40mm | 12V/24V |
AHKC-EKBDA | AC 0-(200-1000)A | DC4-20mA | Φ40mm | 12V/24V |
AHKC-EKC | 0-(500-1500)A | 5V/4V | Φ55mm | ±15V |
AHKC-EKCA | DC 0-(500-1500)A | DC4-20mA | Φ55mm | 12V/24V |
AHKC-EKCDA | AC 0-(500-1500)A | DC4-20mA | Φ55mm | 12V/24V |
AHKC-K | 0-(400-2000)A | 5V/4V | 64*16mm | ±15V |
AHKC-KAA | DC 0-(400-2000)A | DC4-20mA | 64*16mm | 12V/24V |
AHKC-KDA | AC 0-(400-2000)A | DC4-20mA | 64*16mm | 12V/24V |
AHKC-H | 0-(500-3000)A | 5V/4V | 82*32 | ±15V |
AHKC-KA | 0-(500-5000)A | 5V/4V | 104*36 | ±15V |
AHKC-HB | 0-(2000-8000)A | 5V/4V | 132*52 | ±15V |
0-(10000-20000)A | 5V/4V | 132*52 | ±15V | |
0-(25000-40000)A | 5V/4V | 132*52 | ±15V | |
AHKC-HBAA | DC 0-(2000-8000)A | DC4-20mA | 132*52 | 12V/24V |
DC 0-(10000-20000)A | DC4-20mA | 132*52 | 12V/24V | |
DC 0-(25000-40000)A | DC4-20mA | 132*52 | 12V/24V | |
AHKC-HBDA | AC 0-(2000-8000)A | DC4-20mA | 132*52 | 12V/24V |
AC 0-(10000-20000)A | DC4-20mA | 132*52 | 12V/24V | |
AC 0-(25000-40000)A | DC4-20mA | 132*52 | 12V/24V |
When the Hall sensor is used, attention must be paid to the coupling between the primary side coil and assistant side coil in order to get better dynamic characteristics and sensitivity, single conductor that should cram the thread hole of Hall sensor module completely is proposed to use.
When the Hall sensor is used, the best measuring accuracy can be got under rated input current value. When the measured current is much less than the rated value, the primary side can use multi-turns if want to obtain the best accuracy, that is IpNp=rated ampere-turns. In addition, the temperature of the primary side feeder line cannot be more than 80ºC.
When the Hall current sensor is working normally, the auxiliary power supply cannot be more than ±20% of calibration value.
The Hall Current sensor is strictly prohibited to be fallen from high place (≥1m) during installation and use.
Zero and full scale regulator potentiometer can not be adjusted.
Auxiliary power supply is required to be deployed voluntarily.
Power positive and negative poles cannot be inversely connected.